4 Setting up and commissioning User manual SIPLACE TX V2 4.4 Infrastructure at the installation location From software ver sion 711.1 04/2018 168 4.4.2.2 Compressed air connection on the placement m achine 4 Fig. 4.4 - 2…

User manual SIPLACE TX V2 4 Setting up and commissioning
From software version 711.1 04/2018 4.4 Infrastructure at the installation location
167
4.4.2.1 Checking the compressed air supply
Check whether the compressed air supply complies with the prescribed placement machine spec-
ifications (see table in section 3.2
, page 98).
Record the compressed air characteristics at the installation location.
4
WARNING
Risk of injuries!
Risk of injuries from pressurized compressed air lines.
NEVER detach compressed air lines while they are still pressurized.

4 Setting up and commissioning User manual SIPLACE TX V2
4.4 Infrastructure at the installation location From software version 711.1 04/2018
168
4.4.2.2 Compressed air connection on the placement machine
4
Fig. 4.4 - 2 Compressed air unit on the placement machine
Legend for fig.4.4 - 2
(1) Manometer for the placement machine component supply pressure
Target pressure: 0.51 ± 0.01 MPa, 5.1 ± 0.1 bar (display range 0 - 1.0 MPa, 0 - 10 bar)
(2) Manometer for supply pressure of gantries 1 to 2
Target pressure: 0.485 ± 0.01 MPa, 4.85 ± 0.1 bar (display range 0 - 1.0 MPa, 0 - 10 bar)
(3) Manometer for inlet pressure
Target pressure: 0.5 - 1.0 MPa, 5 - 10 bar (display range: 0 - 1.0 MPa, 0 - 10 bar)
(4) Compressed air supply for gantries
(5) Compressed air filter
(6) Compressed air connection
(7) Stop valve in the "OPEN" position
(6)
(1)
(2)
(3)
(5)
(7)
(4)

User manual SIPLACE TX V2 4 Setting up and commissioning
From software version 711.1 04/2018 4.4 Infrastructure at the installation location
169
4.4.3 Main power supply
4
Fig. 4.4 - 3 Position of the power supply in the placement machine
(1) Lock
(2) Main power switch secured to prevent switching on again
(3) Power supply unit (behind the cover)
(1)
(2)
(3)