00198442-01_UM_TX-V2_EN.pdf - 第173页
User manual SIPLACE TX V2 4 Setting up and commissioning From software version 711.1 04/2018 4.4 Infrastructure at the installation location 173 4.4.4 Overview of the microfuses 4 Fig. 4.4 - 7 Overview of the microfuses …

4 Setting up and commissioning User manual SIPLACE TX V2
4.4 Infrastructure at the installation location From software version 711.1 04/2018
172
4.4.3.4 Mains connection - delivery configuration
The mains power connection is configured according to the power supply of the country con-
cerned.
– The placement machine is configured for voltages of 3 x 200 V~ to 3 x 220 V~ ± 10 %; 50/60
Hz.
The placement machines features the mains connection cable WITHOUT connector plug. 4
4
Fig. 4.4 - 5 Description of wires in the mains power cable
– The machine is configured for voltages of 3 x 360 V~ to 3 x 415 V ± 10 %, 50/60 Hz.
The placement machine has a mains power cable WITH a 16A Cekon plug. 4
4
Fig. 4.4 - 6 Assignment in the Cekon plug
1 = (L1): three-phase
2 = (L2): three-phase
3 = (L3): three-phase
4 = (N): neutral conductor
green/yellow = (PE): conductor
PE
L1
L2
L3
N

User manual SIPLACE TX V2 4 Setting up and commissioning
From software version 711.1 04/2018 4.4 Infrastructure at the installation location
173
4.4.4 Overview of the microfuses
4
Fig. 4.4 - 7 Overview of the microfuses
4
Fuse Components Electricity Voltage [V]
F1 Shuttle 6.3 AT 42
F3 Shuttle & Option 6.3 AT 24
F4 Distributor 4.0 AT 24
F5 Monitor 1&2 /CIN 6.3 AT 24
F6 MGCU Supply 6.3 AT 42
F7 Conveyor control 6.3 AT 24
F10 Internal Polyfuse 24

4 Setting up and commissioning User manual SIPLACE TX V2
4.4 Infrastructure at the installation location From software version 711.1 04/2018
174
F11 CSB signal 6.3 AT 24
F12 CSB supply 6.3 AT 24
F13 Diagnostic Supply 3.0 (SMD) 24
F14 Gantry/Head 1 6.3 AT 42/24
F15 Gantry/Head 2 6.3 AT 42/24
F16 Conveyor drives 10.0 AT 42
F19 Gantry 1 6.3 AT 160
F20 Gantry 2 6.3 AT 160
F21 Vision (not used) 6.3 AT 42
F31 FCU 1 16 AC
(external)
27.5
F32 FCU 2 16 AC
(external)
27.5
F33 Station PC 10 AC
(external)
27.5
Fuse Components Electricity Voltage [V]