00198442-01_UM_TX-V2_EN.pdf - 第109页
User manual SIPLACE TX V2 3 Technical data and assemblies From software version 711.1 04/2018 3.5 Placement head 109 3.5.1.2 T echnical data for SIPLACE S peedSt ar (C&P20 P2) 3 SIPLACE SpeedS t ar(C&P20 P2) With…

3 Technical data and assemblies User manual SIPLACE TX V2
3.5 Placement head From software version 711.1 04/2018
108
3.5.1.1 Overview
3
3
Fig. 3.5 - 1 SIPLACE SpeedStar - overview
(1) Connection for the holding circuit of the vacuum pump
(2) "Intermediate distribution board" (under the cover)
(3) Handle
(4) Star motor
(5) DP drive
(6) Nozzle
(7) Pressure control valve
(8) Z motor (linear motor)
(9) Return cylinder
(5)
(1)
(7)
(2)
(3)
(4)
(6)
(8)
(9)

User manual SIPLACE TX V2 3 Technical data and assemblies
From software version 711.1 04/2018 3.5 Placement head
109
3.5.1.2 Technical data for SIPLACE SpeedStar (C&P20 P2)
3
SIPLACE SpeedStar(C&P20 P2)
With component camera type 48
Component range
*a
*)a Please note that the placeable component range is also affected by the pad geometry, the customer-
specific standards, the component packaging tolerances and the component tolerances.
0.12 mm x 0.12 (0201 metric) to 2220, Melf, SOT, SOD, Bare-
Die, Flip-Chip
Component spec.
Max. height
Min. lead pitch
Min. lead width
Min. ball pitch
Min. ball diameter
Min. dimensions
Max. dimensions
Max. weight
2 mm
*b
/ 4 mm
70 µm
30 µm
100 µm
50 µm
0.12 mm x 0.12 mm
8.2 mm x 8.2 mm
1 g
*)b Only 2 mm possible for SIPLACE TX2i.
Programmable set-down
force
Touchless Placement, 1.3 N ± 0.5 N (standard)
0.5 N - 4.5 N
Nozzle types 60xx
X/Y accuracy
*c
*)c The accuracy values fulfill the conditions in the SIPLACE scope of supply and services.
± 25 µm/3σ
Angular accuracy ± 0.5° / 3σ
Illumination level 5

3 Technical data and assemblies User manual SIPLACE TX V2
3.5 Placement head From software version 711.1 04/2018
110
3.5.2 Sensor for the component reject bin
The sensor for the component reject bin monitors whether the reject bin is seated correctly in its
mount.
– If the reject bin was not inserted correctly, the machine cannot be started.
– If the reject bin jumps out of its mount during the placement process, the machine is stopped
immediately to avoid a head crash.
3.5.3 Vacuum pump
Item no. 03157734-xx vacuum pump
Item no. 03165711-xx frequency converter (optional)
3.5.3.1 Overview
The vacuum pump is a standard for the SIPLACE SpeedStar and is fitted behind the cover at lo-
cation 1, in the placement machine frame.An optional frequency converter is available
3
Fig. 3.5 - 2 Overview - vacuum pump
(1) Installation location for vacuum pump
(2) Vacuum pump
(T) Direction of PCB transport
(1)
(2)