00198442-01_UM_TX-V2_EN.pdf - 第284页
6 Station extensions Use r manual SIPLACE TX V2 6.7 Stationary came ras From software version 711.1 04/2018 288 6.7.1.2 T echnical dat a 6 Component dimen sions 0.2 mm x 0.2 mm up to 16 mm x 16 mm for single component me…

User manual SIPLACE TX V2 6 Station extensions
From software version 711.1 04/2018 6.7 Stationary cameras
287
6.7 Stationary cameras
6.7.1 Stationary P&P component camera (type 25) 16 x 16, digital (FC camera)
Item no. 00588101-xx Stationary camera for the Twin head, type
6
Fig. 6.7 - 1 Stationary P&P component camera (type 25) 16 x 16, digital (FC camera)
(1) Camera housing with integral camera and camera amplifier
(2) Glass plate - illumination and lens levels below
6.7.1.1 Safety instructions
6
(1)
(2)
WARNING
Risk of collisions!
When changing the placement head from a TwinStar/VHF to a SpeedStar, the SpeedStar
collides with the camera housing.
Dismantle the stationary component camera for the TwinStar.
When changing the placement head from a TwinStar to a MultiStar, the stationary
component camera is fitted in the bottom position.

6 Station extensions User manual SIPLACE TX V2
6.7 Stationary cameras From software version 711.1 04/2018
288
6.7.1.2 Technical data
6
Component dimensions 0.2 mm x 0.2 mm up to 16 mm x 16 mm for single component
measurement
Component range 0402 to SO, PLCC, QFP, sockets, plugs, BGA, special components,
bare dies, flip-chips, shields
Min. lead pitch 0.25 mm
Min. lead width 0.1 mm
Min. ball pitch 0.14 mm
Min. ball diameter 0.08 mm
Field of vision 19.4 mm x 19.4 mm
Illumination type Front-illumination (6 levels, programmable as required)

User manual SIPLACE TX V2 6 Station extensions
From software version 711.1 04/2018 6.7 Stationary cameras
289
6.7.2 Stationary P&P component camera (type 33) 55 x 45, digital (IC camera)
Item no. 00588100-xx Stationary camera fore the CPP head /TH, type 33
6
Fig. 6.7 - 2 Structure for the stationary P&P component camera, type 33, 55 x 45, digital
(1) Camera housing with integral camera and camera amplifier
(2) Glass plate - illumination and lens levels below
6.7.2.1 Safety instructions
6
(1)
(2)
WARNING
Risk of collisions!
When changing the placement head from a TwinStar/VHF to a SpeedStar, the SpeedStar
collides with the camera housing.
Dismantle the stationary component camera for the TwinStar.