00198442-01_UM_TX-V2_EN.pdf - 第98页

3 Technical data and assemblies User manual SIPLACE TX V2 3.2 Ambient conditions and connection va lues From software version 711.1 04/2018 98 3.1.4 Component supply 3.2 Ambient conditions and connection values 3.2.1 Amb…

100%1 / 304
User manual SIPLACE TX V2 3 Technical data and assemblies
From software version 711.1 04/2018 3.1 Performance data
97
3.1.3 PCB conveyor data for SIPLACE TX1/TX2/TX2i
3
Dual conveyor
(standard)
Dual conveyor in
"single conveyor"
(optional) mode
Board dimensions
(width
*a
x length)
*)a When using board widths > 375 mm, make sure that the peripheral modules can also process these
board widths.
45 mm x 50 mm to
260 mm x 375 mm
45 mm x 50 mm to
460 mm x 375 mm
Stationary conveyor side Outer /outer
Right / right
Left / left
Outside
Automatic electrical width adjust-
ment
Standard
PCB thickness
Standard 0.3 mm to 4.5 mm
PCB warpage See page 133
PCB weight
*b
Standard
*)b The board weight value refers to the weight of the board plus the weight of the components.
Max. 2.0 kg Max. 2.0 kg
Clearance on PCB underside 33 mm
PCB conveyor height
Option
Standard
Option SMEMA
900 mm
930 mm
950 mm
Type of interface SMEMA or The Hermes Standard
Component-free PCB handling
edge
3 mm
PCB changeover time
Dual conveyor 1,3 seconds
*c
0 seconds
*d
*)c With the "Convoy Mode" option. Without this option 1.8 seconds.
*)d 0 seconds in asynchronous mode
3 Technical data and assemblies User manual SIPLACE TX V2
3.2 Ambient conditions and connection values From software version 711.1 04/2018
98
3.1.4 Component supply
3.2 Ambient conditions and connection values
3.2.1 Ambient conditions for packaging, transportation and storage
3
3.2.2 Environmental conditions for operation
3
Component supply Tracks occupied
SIPLACE TX
With C&P20 P2
With CPP
With CPP /TH
With CPP or TwinHead and JTF-ML at location 1
38 feeder modules, each with 8mm X
40 feeder modules, each with 8 mm X
40 feeder modules, each with 8 mm X
28 feeder modules, each with 8 mm X
Technical data
Tape reel diameter to 330.2 mm (13")
Component trolley changeover time < 1 minute
Temperature range Between -25°C and 55°C
Atmospheric humidity Up to 95%
Ambient pressure Up to 3000 m height without pressure equalization
Room temperature
SIPLACE TX
Between 15°C and 35°C
Atmospheric humidity 30% to 75%
(on average not higher than 45%, so that there is no risk of
condensation on the placement machine.)
Ambient pressure > 750 mbar (corresponds to 1700 m above mean sea level)
User manual SIPLACE TX V2 3 Technical data and assemblies
From software version 711.1 04/2018 3.2 Ambient conditions and connection values
99
3.2.3 Compressed air supply and compressed air specification
3
Compressed air supply
Compressed air pressure val-
ues
p
min
p
max
0.5 MPa = 5.0 bar
1.0 MPa = 10 bar
Operating pressure 0.48 MPa ± 0.025 MPa (4.8 bar ± 0.25 bar)
Compressed air connection 1/2" hose connection
Compressed air consumption
*a
Placement head configuration Compressed air
consumption
*b
with
vacuum pump
Compressed air con-
sumption without vac-
uum pump
*c
SIPLACE TX2i/TX2 C&P20 P2/C&P20 P2
CPP / CPP
CPP / TH
120 Nl/min
No option
No option
No option
260 Nl/min
220 Nl/min
SIPLACE TX1 C&P20 P2
CPP
TH
70 Nl/min
No option
No option
No option
130 Nl/min
130 Nl/min
Compressed air specification acc. to ISO 8573
Particle size (ISO class 3) 5 µm
Particle density (ISO class 3) 5 mg/m³
Maximum oil content
(ISO class 1)
Particle density 0.01 mg/m³
Pressure dewpoint (ISO class 4) Dewpoint + 3°
*)a Average consumption values.
*)b Under normal atmospheric conditions at 20°C and 1013 hPa.
*)c Optional