2 Operational safety Use r manual SIPLACE TX V2 2.6 Residual voltages and discharge times From software version 711.1 04/2018 86 2.6.5 Compressed air conditions af ter switching off at the main switch When the main switc…

100%1 / 304
User manual SIPLACE TX V2 2 Operational safety
From software version 711.1 04/2018 2.6 Residual voltages and discharge times
85
2
Fig. 2.6 - 1 Main switch (S1) at location 2
(1) Main switch (S1)
2.6.4 Main switch switched off - placement machine disconnected from the mains
power supply
2
(1)
DANGER
Lethal voltages in the power supply unit!
The power supply unit has components (capacitors) which can still conduct potentially le-
thal voltages for approx. 5 minutes, even when the placement machine has been switched
off and the mains plug has been disconnected.
When working on the power supply, switch off the main switch, secure it to prevent
switching on again, disconnect the placement machine from the power network and
wait 5 minutes until the capacitors have discharged.
Test to check that there is no remaining voltage supply. See the procedure described
in the service manual.
Only ASM Assembly Systems GmbH&Co.KG service engineers or the machine
owner's service engineers, who have been trained by ASM, may perform work on the
power supply and the safety cutoff (CBS).
2 Operational safety User manual SIPLACE TX V2
2.6 Residual voltages and discharge times From software version 711.1 04/2018
86
2.6.5 Compressed air conditions after switching off at the main switch
When the main switch is switched off or the mains supply to the placement machine fails, the elec-
trically-controlled main valves of the compressed air unit will close (item 1 in fig. 2.7 - 1
, page 88).
The pressure will drop to 0 MPa (0 bar) within 5 seconds. The components before the electrically-
controlled main valves will remain pressurized.
User manual SIPLACE TX V2 2 Operational safety
From software version 711.1 04/2018 2.7 Disabling the compressed air supply and discharging the pressure
87
2.7 Disabling the compressed air supply and discharging
the pressure
The compressed air unit is at location 2 (see fig. 4.4 - 1, page 166). The compressed air working
pressure of the placement machine is set to 0.51 ± 0.01 MPa (5.1 ± 0.1 bar). The position of the
compressed air unit is shown at item 1 in fig. 2.7 - 1
, page 88. The supply of compressed air to
the placement machine can be interrupted with the shutoff valve (item 2 in fig. 2.7 - 1
, page 88).
Use the placement machine key to release the cover lock.
Lift the cover (see fig. 2.7 - 1, page 88).
Turn the lever of the shutoff valve (item 1 of fig. 2.7 - 1, page 88) from the vertical to the hor-
izontal position.
Monitor the operating pressure manometer (item 5 in fig. 2.7 - 1, page 88). When the place-
ment machine is switched on, the pressure discharges to 0 MPa (0 bar) within 1 minute.
2
CAUTION
Interruption to compressed air supply!
When the placement machine is switched on, do not use the stop valve to interrupt
the compressed air supply for more than 30 minutes.
If you need to shut off the pneumatic system for longer in order to carry out preven-
tive maintenance or servicing work, you must switch the placement machine off at
the main switch and disconnect it from the power supply.