00198442-01_UM_TX-V2_EN.pdf - 第123页

User manual SIPLACE TX V2 3 Technical data and assemblies From software version 711.1 04/2018 3.5 Placement head 123 3.5.5.1 T echnical data T win St ar SIPLACE T winSt ar with component camera type 33 (fine pitch ca mer…

100%1 / 304
3 Technical data and assemblies User manual SIPLACE TX V2
3.5 Placement head From software version 711.1 04/2018
122
3.5.5 SIPLACE TwinStar for high precision IC placement
3
Fig. 3.5 - 10 SIPLACE TwinStar for high precision IC placement
3
(1) Pick&Place module 1 (P&P1)
(2) Pick&Place module 2 (P&P2)
(3) DP axis
(4) Z axis drive
(5) Incremental distance measuring system for the Z axis
User manual SIPLACE TX V2 3 Technical data and assemblies
From software version 711.1 04/2018 3.5 Placement head
123
3.5.5.1 Technical data Twin Star
SIPLACE TwinStar
with component camera type 33
(fine pitch camera)
with component camera type 25
(flip chip camera)
Component range
*a
0402 to SO, PLCC, QFP, BGA, special
components, bare dies, flip-chips
0201 to SO, PLCC, QFP, sockets, plugs, BGA,
special components, bare dies, flip-chips,
shields
Component specs
Max. height
Min. lead pitch
Min. lead width
Min. ball pitch
Min. ball diameter
Min. dimensions
Max. dimensions
Max. weight
*b
25 mm
300 µm
150 µm
350 µm
200 µm
1.0 mm x 0.5 mm
55 mm x 45 mm (single measurement)
75 mm x 10 mm (multiple measure-
ment)
100 g
25 mm
250 µm
100 µm
140 µm
80 µm
0.6 mm x 0.3 mm
16 mm x 16 mm (single measurement)
100 g
Programmable set-down
force
1.0 N - 15 N 1.0 N - 15 N
Nozzle types 5xx (standard)
20xx / 28xx (with nozzle adapter 20xx/28xx on 5xx)
Special nozzles, gripper
Nozzle spacing for P&P
heads
70.8 mm 70.8 mm
X/Y accuracy
*c
± 28 µm/3σ ± 22 µm/3σ
Angular accuracy ± 0.05° / 3σ ± 0.05° / 3σ
Illumination level 6 6
Possible illumination level
settings
256
6
256
6
*)a Please note that the placeable component range is also affected by the pad geometry, the customer-specific standards, the
component packaging tolerances and the component tolerances.
*)b Component plus nozzle or gripper.
*)c The accuracy values fulfill the conditions in the SIPLACE scope of supply and services.
3 Technical data and assemblies User manual SIPLACE TX V2
3.6 Gantry system From software version 711.1 04/2018
124
3.6 Gantry system
3.6.1 Position of gantries (SIPLACE TX2 /TX2i)
3
Fig. 3.6 - 1 Position of gantries - example of SIPLACE TX2i - location 2
(1) Gantry 1
(2) Y axis, gantry 1 and gantry 2
(3) Gantry 2
(T) Direction of PCB transport
(3)
(2)
(1)