80S-20贴片机.pdf - 第282页
8 IC Head S IPLACE 80S-20/F4 Service Manual 8.5 Servicing W ork on the Pneum atic System Edition 01/97 8 - 20 6HUY LFLQJ:R UNRQWKH3QHXPDWLF6\ VWHP 7 RR OV( TXLS PHQW DQG &RQVX PDEO HV 6S DUH…

SIPLACE 80S-20/F4 Service Manual 8 IC Head
Edition 01/97 8.4 Servicing Work on the Dr Axis
8 - 19
Key to Fig. 8.4.3
● The axis display should read 0 digits. If this is not the case, proceed as described for calculation of the zero
point correction for the z axis (see section 8.3.9, page 8 - 14).
ZPC
NEW
= ACTUAL - DESIRED + ZPC
OLD
ZKHUH'(6,5('
ZPC
NEW
= ACTUAL + ZPC
OLD
1 Station monitor 2 Stop pin on the nozzle
A Nozzle at IC head, dr axis 0° position
video image from IC camera
B Position of the rectangular nozzle, type 416
A
1
2
B

8 IC Head SIPLACE 80S-20/F4 Service Manual
8.5 Servicing Work on the Pneumatic System Edition 01/97
8 - 20
6HUYLFLQJ:RUNRQWKH3QHXPDWLF6\VWHP
7RROV(TXLSPHQWDQG&RQVXPDEOHV
6SDUH3DUWV
5HSODFH6ROHQRLG9DOYHIRU=$[LV&ODPSLQJ'HYLFH
See item 1 in Fig. 8.5.1 page 8 - 21
● Loosen the two slotted screws that fix the solenoid valve in place.
● Remove the connecting cable.
● Fix the new solenoid valve in place and reconnect to the power supply.
PLEASE NOTE
The small red push-button is used only to manually actuate the solenoid valve, i.e. to release the clamping
device.
)URPLWHPQXPEHU
Hexagon socket head screw key, set
SITEST program
UNISILKON L250L 00310259-01
)URPLWHPQXPEHU
Valve (clamping device for z axis) 00306387-02
Valve (vacuum) 00306389-03
Valve (forced air) 00306388-02
Collet bush PK-3 00303552-01
O-ring 3 x 1 FPM 80SB 00301723-01
O-ring 5 x 1.5 NBR 70B 00305480-01
Vacuum nozzle for the IC head 00318370-01
O-ring 8 x 1 NBR 70B 00201179-01
Silencer G-1/8 CV05 HS 00308498-01
Hose connector T-PK-3 00303088-01
Nipple with male threaded end CN-M3-PK-3 00305374-01