12 Vision systems SIPLACE 80S-20/F4/F5 Service Manual
12.6 Coplanarity Option Edition 09/99
12 - 44
12.6.16.1Preconditions
Aside from coplanarity, the machine is completely calibrated.
12.6.16.2 V 403.04: Performing Calibration
Procedure: As described below for Version > 404.01 with the following difference:
12.6.16.3 > V 404.01: Performing Calibration
Turn the machine on and start the SITEST program.
Carry out the “total reference run” in the SITEST program.
Pick up nozzle no. 417 with the IC head.
Select the function menu “IC HEAD” -> “COPLANARITY”.
The display of the initial positions of the new coplanarity sensor follows (configuration data)
X = 444000 Y = 595000 Z = 17000
Select the function menu -> “CALIBRATE MODULE”
When the request appears on the screen, place the coplanarity calibration tool in the middle of the cal-
ibration tool pocket on the stationary side of the conveyor.
Close the protective hoods and actuate the “Start” button.
The calibration starts automatically. The calibration values determined are displayed.
Possible error messages during this process:
- X-Y- position not located.
Possible causes:
- Position of coplanarity sensor is wrong because:
- In case of 404.01: Wrong, i.e., old coplanarity module ("LCM150") - and thus the old
X-, Y- (and Z) -position - were entered.
- In the case of machines with dual conveyors (left-hand or right-hand conveyor side = stationary):
spacer washer (total 2 mm thick) between the sensor bracket and the optional carrier or nozzle
changer were not installed or more/less than two washers (1mm each) were installed
(see Fig. 12.6.8 -> 5).
- In case of machines with a single conveyor: Spacer washers were installed at the
above location ( = incorrect).
- Focus outside of tolerances
Possible causes:
- Calibration tool damaged or not picked up.
- Diameter of calibration tool not within tolerances
Possible cause:
- Nozzle projects over calibration tool -> Wrong nozzle picked up (= not 417).
SIPLACE 80S-20/F4/F5 Service Manual 12 Vision systems
Edition 09/99 12.6 Coplanarity Option
12 - 45
If desired, actuate the “Display” button to see the measured values.
Terminate the menu “COPLANARITY”.
Terminate the SITEST program.
Answer “YES” to the question being displayed: “Store the data?”
The offset values for X, Y and Z are entered in the real.ma data under coplanarity_2_x /.... _y /.... _z .
Press EMERGENCY OFF and remove the calibration tool.
As the final step, check whether the IC camera and flip-chip camera function.
 ,Q&DVHRI3UREOHPVRU(UURUV
12 Vision systems SIPLACE 80S-20/F4/F5 Service Manual
12.6 Coplanarity Option Edition 09/99
12 - 46
&KHFN3RVLWLRQRI&RSODQDULW\6HQVRU!9[[
12.6.17.1Overview
NOTE
For the execution of test commands 3 and 8 see Section 12.6.18, Run Data Protocol (German: ADP).
You can utilize test command 4 (see Fig. 12.6.9) to check whether the laser track strikes the leads.
- The component to be measured is optically centered after test command 4 is called up. Instead of being
moved over the coplanarity sensor, it is moved over the camera., i.e., the measurement process is there-
fore simulated.
- The midpoint of the IC camera (crosshairs) corresponds to the focus point of the coplanarity sensor.
12.6.17.2Procedure (> V 403.xx)
Execute only in case of software version 403.04 -> D:\DAT\SST.MA, speed factor:
If this value is > 200 reduce the value to 200 (= higher accuracy).