SIPLACE 80S-20/F4/F5 Service Manual 12 Vision systems
Edition 09/99 12.6 Coplanarity Option
12 - 41
Move the component changeover table into the machine or install the right-hand component table with the
assistance of a 2nd strong person.
Set up the reassembled component table properly in accordance with the "set-up".
The component table must always be completely equipped (see above DANGER note).
If applicable, move the wafflepack changer back into the machine.
Remove all of the components and tools lying in the machine.
Plug in the connectors of the WPC or the component changeover table in the correct sequence -> First
the interface cable, then the power cable.
 &KHFNLQJWKH6DIHW\&LUFXLW
After exchanging the cable "coplanarity terminal panel" and after every other step involving its wiring, the
laser shut-off unit must be checked explicitly, as described here.
DANGER O O O
As with all the retrofitting, the following jobs are to be performed only by the Siemens service engineer or
by a Siemens-trained service engineer of the customer.
Before doing this work the service engineer in question must receive instruction from a laser protec-
tion officer.
The laser shutoff is only to be checked indirectly , i.e., with the help of the test connector.
To check the sensor cable it is to disconnected directly at the coplanarity option processing unit and the test
connector is to plug in on in the processing unit on the where the sensor cable is removed from. The laser its-
elf (coplanarity sensor) is therefore not running during this check.
The laser shut-off must be checked during all subsequently named interruptions in protection, once with the
key-operated switch locked ("0") and once with the key-operated switch in the service position ("I").
12.6.15.1Interruptions in Protection which must be Checked
Perform the following checks as described in detail below under “Steps in the Check” Section 12.6.15.2 bes-
chrieben:
- Open and close each of the 4 protective covers/hoods:
Input, output, protectve hoods (left and right).
- Actuate and release each of the 3 EMERGENCY OFF buttons: input, output and WPC
- Electrically isolate and connect the 2 component tables from/to the machine.
Sequence while pulling the plug-in connectors -> see WARNING below.
12 Vision systems SIPLACE 80S-20/F4/F5 Service Manual
12.6 Coplanarity Option Edition 09/99
12 - 42
12.6.15.2Steps in the Check
The following steps are identical with V 403.04 and V404.01:
Before you turn the machine on: Remove all loose parts and tools from the machine.
The machine must be turned off.
Make certain that the key-operated switch is locked (position "0").
Unplug the
FRSODQDULW\VHQVRUFDEOH
from the assembly (see Fig. 12.6.7).
Plug the coplanarity test connector
WRWKH
coplanarity option processing unit onto the connector previ-
ously removed (test connector configuration and LED allocation: see Fig. 12.6.6).
Close all of protective devices.
Turn the machine ON. The control remains “OFF”:
- None of the 4 LEDs on the connected test connector is to light up.
NOTE
The LEDs on the coplanarity processing unit (in the control unit) are not activated in the identical manner as
the LEDs on the test connector. Therefore the activation and deactivation of LEDs must always be con-
firmed at the test connector. The coplanarity sensor is turned back off 20 minutes after the last activation.
Therefore the checks must be performed within this period of time.
CAUTION O
In this case, the calibration procedure subsequently started via SITEST is merely used to turn on the sensor,
i.e., it is NOT to be STORED.
Load the SITEST program and select:
"Calibrate" -> "Coplanarity" menu -> "Calibrate module" menu.
Turn the control “ON” (“Start” button).
The machine will perform a reference run.
All 4 LEDs on the test connector must light up.
Now open and close all 4 protective covers one after the other, checking whether the LEDs on the test
connector are activated:
After one protective cover is opened -> None of the 4 LEDs is to light up.
After the individual protective cover or all protective covers is/are closed and the “ON” button is acti-
vated -> all 4 LEDs must light up.
Press and release all 3 “EMERGENCY OFF” buttons one after the other, checking whether the LEDs on
the test connector are activated:
After one “EMERGENCY OFF” button is activated -> None of the 4 LEDs is to light up.
After the “EMERGENCY OFF” button is released and control “ON” is activated -> all 4 LEDs must
light up.
SIPLACE 80S-20/F4/F5 Service Manual 12 Vision systems
Edition 09/99 12.6 Coplanarity Option
12 - 43
WARNING O O
If, by way of this exception, the connectors must be unpugged while the machine is ON, always unplug the
round connector (power supply) of the component changeover table and / or of the WPC first.
After you unplug the power supply connector you must wait until the 30 V indicator goes out before unplug-
ging the interface connector (square plug).
Unplug the round connector and then the square one on the right-hand component table.
After the (square) interface connector is pulled out -> none of the 4 LEDs is to light up.
After the connectors are plugged in (in reverse order) and control is “ON”.
-> All 4 LEDs must light up.
Follow the same procedure for the component table on the left-hand side of the machine.
Turn key operating switch to Position "I" (service position) and repeat the procedure described above.
Afterwards, lock the key-operated switch ("position "0").
Press the “EMERGENCY OFF” button and turn the machine off.
Proceed to the steps described in Section 12.6.16.
 &DOLEUDWLRQZLWKWKH6,7(673URJUDP
DANGER O O O
Only the Siemens service engineer or the Siemens-trained service engineer is permitted to put the machine
back into service the first time this is done following service work on the coplanarity option.
Bridging of protective equipment is not permitted.
For all subsequent jobs the key-operated switch must be locked (position "0").
CAUTION O
The calibrating sequence subsequently started via SITEST is just utilized here to turn on the sensor, i. e.,it is
not to be stored.
NOTE
The Re-calibration of the coplanarity option is always required after the coplanarity sensor and/or the sensor
retaining bracket is exchanged and re-installed, see Section 12.6.16.