8.26 SIPLACE Vision Enhancements
The SIPLACE Vision system has been enhanced as follows.
8.26.1 New Camera Interface GigE
SIPLACE Vision now also supports GigE cameras.
8.26.2 Binning Can Be Disabled
With the so called "binning" 2x2 pixels (for sensor system type 30: 4x4 pixels) are combined to one
pixel. Thus, the resolution is lower and the measure time reduced. Binning is performed
automatically for some components.
As of this station software version, binning can be disabled in the algorithm parameters on the
SIPLACE Vision GUI (value "1" = no binning). The setting is valid for the current sensor type only.
The parameter is available for all components and can be used on all placement machines.
8.26.3 Measuring Dies with Pattern Matching
Usually, the components are measured by SIPLACE Vision on the basis of their electrical
connectors which are detected by filters specially adapted to the connector geometry. However,
some dies only show internal structures for which no suitable filters exist. With "pattern matching" it
is now possible to measure such structures more accurately.
At first, the pattern used for measuring the die will be created and taught by means of a teaching
wizard. On the basis of a reference die, points get measured at which the brightness strongly
changes in the picture. These points form the pattern.
All relevant calculations are performed automatically by the system. However, if necessary, the
operator may manipulate the teaching procedure by setting parameters. I.e., parts of the
component may be excluded from the teaching procedure (while not sure enough).
During the measurement of the component the position is detected at which the picture content
best matches the taught pattern points. At low concordance the component will be rejected.
8.26.4 New Pin Types: THT Round Pin and THT Square Pin
Two new pin types have been introduced to place THT components (Through Hole Technology):
THT round pin and THT square pin. The height of the components has to be described as follows
in SIPLACE Pro:
– Height = pin length + base unit height
– A creep distance with height = pin length
Thus, an inspection with correct focussing can be performed in SIPLACE Vision.
8.26.5 Storing Vision Data
Until now, some Vision data as e.g. illumination values could be stored line- or station-specifically
without any security check.
As of this station software version, the same rules apply for such Vision data as for the other Vision
data (geometrical values). I.e., if the SIPLACE Pro security is enabled, the user must have the
corresponding authorization on the SIPLACE Pro computer.
SIPLACE Station Software 70x / Feature Description Ausgabe 05/2014 Edition
141
8.27 Supported SIPLACE Pro Enhancements
The station software supports the placement of boards with a high number of panels.
Features (V707.1: compatible mode V706.2)
8.28 Twin Head / CPP Placement Heads on SIPLACE CA-Series
Compatible mode: Not supported
Additionally to the C&P20 M placement head, the CPP and Twin Head (also Twin Head HF)
placement heads are supported on the SIPLACE CA-series placement machines as of this station
software version with the following restrictions.
– Stationary cameras can only be installed on the locations 1 and 3.
– The Twin Head can only be installed on location 3.
– The CPP placement head is only supported in the high position on SIPLACE Wafer Systems.
CPP placement head
The CPP placement head can be used in Pick&Place mode and on SIPLACE Wafer Systems as
well. FlipChip and DieAttach modes are supported on the SIPLACE Wafer Systems. Dip modules
may be used.
The nozzle changer for the CPP placement head has 5 magazines for 20xx nozzles with 12
garages each and 1 magazine for 28xx nozzles with 9 garages. If desired, this configuration may
be changed, e.g. 6 magazines for 20xx nozzles.
The 33 component camera type is supported for placement in Pick&Place mode and the 30
component camera type on SIPLACE Wafer Systems.
Twin Head
The Twin Head is used in Pick&Place mode only.
The nozzle changer for the Twin Head has maximum 12 magazines with 2 garages each on the
locations 1 and 3 and maximum 10 magazines with 2 garages each on the locations 2 and 4.
The 33 and 25 component camera types are supported.
Available placement head configurations on SIPLACE CA-series
4*C&P20 M
2*C&P20 M in PA1 and 2*CPP in PA2
4*CPP
2*C&P20 M in PA1 and CPP / TH in PA2
2*CPP in PA1 and CPP / TH in PA2
SIPLACE Station Software 70x / Feature Description Ausgabe 05/2014 Edition
142
8.29 C&P20 P Placement Head on SIPLACE X-Series S
Compatible mode: Not supported
The C&P20 P placement head was introduced for the SIPLACE X4i S placement machine in the
previous station software version. As of the current station software version, this placement head is
additionally supported on the SIPLACE X2 S, X3 S and X4 S placement machines.
The C&P20 P placement head is supported on the same locations as the C&P20 A placement
head and uses the same component camera types (23 and 41), too.
The 4xxx nozzle type is supported on all locations.
Additionally, the diagnostic method for the pressure control valve of the C&P20 P placement head
has been improved. If applicable, detailed error messages and warnings will be displayed. The
machine will be stopped if the pressure supply fails or the pressure control valve gets superheated.
8.30 WPC5/WPC6 on SIPLACE X-Serie S
Compatible mode: Not supported
The station software supports the option to put a WPC5/WPC6 with the new WPC 40 X X-table on
the X2 S, X3 S and X4 S placement machines. However, the hardware will not be released for
series production in this version.
The WPC5/WPC6 and the WPC 40 X occupy the tracks 11 – 40. Further modules, such as X-
feeders may be set up on the tracks 1 – 10.
The WPC 40 X can be selected for location 2 in the Auto Configuration. A single WPC5/WPC6
cannot be configured without the X-table. An XFCU must have been installed.
Location 2 is displayed similarly as for the SX-series placement machines with WPC in the Main
view. WPC5/WPC6 and WPC 40 X can be selected via the corresponding buttons in the Setup
view.
The Twin Head and CPP placement heads and also new nozzle changer / reject bin positions are
supported for this option.
SIPLACE Smart Pin Support supports the option on the X3 S and X4 S placement machines.
8.31 SIPLACE X4i S micron – Enhancements
Compatible mode: Not supported
CPP placement head and SIPLACE JTF-M feeder
As of this SIPLACE Pro version, the CPP placement head and the SIPLACE JTF-M feeder are
supported on the SIPLACE X4i S micron placement machine.
Placement Process for Component Type 03015
When placing components of the 03015 type, the user is guided through a similar placement
process as for the 01005 component type on the SIPLACE X4i S micron placement machine.
If the 03015 placement process is selected in SIPLACE Pro, the required process parameters such
as cameras, nozzles, travel profiles and placement forces will be set automatically.