c921199.R00_EN.pdf - 第14页

vi Before using the machine n How to hold the feeder How to hold the feeder Handle 63006-9L-10 Hold the rear portion of the feeder body with one hand and hold the feeder handle with the other hand. c CAUTION · Don’t hold…

100%1 / 86
v
Before using the machine
n
Cautions after installing the feeder
· Don’t push the installed feeder rightward or leftward.
c
CAUTION
Be careful not to push the feeder set on the feeder plate rightward or leftward, or pickup error may be caused.
Cautions after installing the feeder
63005-9L-10
n
Handling the tail cover
· An edge cutter (with a sharp blade) is installed on the tail cover for cutting used top tape. If the tail cover should be
damaged somehow, the blade may be exposed. Pay attention when handling the tail cover or injury may be caused.
Handling the tail cover
Edge cutter
(With a sharp blade)
Tail cover
63012-9L-00
vi
Before using the machine
n
How to hold the feeder
How to hold the feeder
Handle
63006-9L-10
Hold the rear portion of the feeder body with one hand and hold the feeder handle with the other hand.
c
CAUTION
· Don’t hold the clamping lever part or your hand may be pinched, causing injury.
· Take care not to hold the connector or sprocket part or the feeder may be damaged.
· Don’t touch the EL box which is heated to high temperature.
Cautions when holding the feeder
Sprocket part
Connector part
Clamping lever part
63007-9L-20
vii
Before using the machine
n
"Offline setup station"
Specifications: single-phase AC100 to 230 V ± 10%, 50Hz/60Hz, Electrical power of 170 VA (for Offline setup station.)
Two types of AC power harnesses for "Offline setup station" are available: One for Japanese market (up to AC125V) and
one for other markets (up to AC250V).
AC power harness
“Offline setup station”
AC power harness
for Japan
AC power harness
for other markets
Light blue: AC (N)
Brown: AC (L)
Green/Yellow: AC (GND)
n Wiring harness
Green/Yellow
Light blue
Brown
63009-9L-20
c
CAUTION
Take care not to connect the harness for Japan to power supply of AC125V or higher.
c
CAUTION
Make sure to ground the instrument before connecting to the power supply.
n
Master feeder
This master feeder is a jig that is intended to adjust the pickup position of the F3 feeder.
When one year or longer has elapsed from the date marked on the calibration label, it is recommended to calibrate the
master feeder.
Master feeder angle
Calibration label
63010-9L-00