Page 3-36 444C-E-OMA03-A01-01 444C-619TE Others 3-6-7 Nozzle Clogging Error If the clogging of nozzle or the like is detected upon automatic operation, the message appears and the operation aborts. • In this case, the ch…

100%1 / 138
Page 3-35
FUNCTIONS
3
444C-E-OMA03-A01-01
Others
3-6-6 Operating Procedure against Pick-up Instability Error
If a pick-up instability error is detected, the machine comes to an immediate stop with the chip
above the ejection box without mounting it.
The detailed information appears.
HD1 NP5=115 ADR3=2125TEST
M5 X50.00 Y51.00 BL2 c=SEQ00005
HD1 : Head number
NP5 : Nozzle position number
115 : Nozzle number
ADR3 : Feeder address
2125TEST : Parts name
M5 : Mount sequence number
X50.00 : Mount coordinate X
Y51.00 : Mount coordinate Y
BL2 : Block number
SEQ00005 : Comment on the mounter data
Check the details of the error, and then press
OK .
If more than one error has occurred simulta-
neously, the error-detail windows open in
sequence.
Resuming the (mounting) operation carries out
the chip-ejecting action and returns to the
automatic operation.
In this case, since the chip is carried back
without being mounted, it will be retry-mounted
last.
Page 3-36
444C-E-OMA03-A01-01
444C-619TE
Others
3-6-7 Nozzle Clogging Error
If the clogging of nozzle or the like is detected upon automatic operation, the message appears
and the operation aborts.
In this case, the chip may be adhered to the
nozzle. Press OK to return to the main menu.
Turn OFF the servo switch.
Check and clean the tip of the nozzle.
Turn ON the servo swith.
Refer to the vacuum-sensor values at the
output check screen under the machine
adjustment screen.
3-6-8 Machine Adjustment Screen
When Vacuum Sensor check in the option configuration is set to ON, the vacuum-sensor values
are displayed on the output check screen under the machine adjustment screen.
The vacuum-pump-ON state and the air-blow-
ON state can be converted into numbers.
Please note that the sensor values are subject to change without notice for improvements be
cause these are reference values.
sutatspmuP sutatsevlaV .oNelzzoN )ecnerefeR(eulavrosneS )ecnerefeR(gniggolcelzzoN
NOpmupmuucaVNOmuucaV
502002otesolC571
011512otesolC002
511522otesolC002
eromro021032otesolC002
Sensor values
Reference sensor values
Page 3-37
FUNCTIONS
3
Others
444C-E-OMA03-A01-01
3-6-9 Recovery mount function against chip mount error (Only
when an optional pick-up sensor is available)
At the mount state check screen, the head camera checks the mount state. Then you can select
whether or not to recovery-mount the mount-error components.
1. Selection whether or not to use the recovery mount function
When the item Chip mount error recovery
on the option configuration screen is set to
Use (1), mount-error components can be
recovery-mounted automatically. When it is
set to Unuse (0), mount-error compo-
nents are not recovery-mounted because
they are considered to have already been
mounted.
Set Chip mount error recovery to 1 (Use).
To continue conventional operation, set it to 0
(Unuse).
2. When Chip mount error recovery is set to Use (1)
If a chip-mount error occurs during operation,
the mount state check screen displays.
When you wish to check the mount state of the
mount-error components, press Yes.
Pressing Yes displays the mount state check
screen.
Pressing No returns the screen to the immedi-
ate-stop screen, and recovery-mounts the
mount-error components at the time when
production resumes.