444CEOM1-CM202.pdf - 第135页
Page 3-37 FUNCTIONS 3 Others 444C-E-OMA03-A01-01 3-6-9 Recovery mount function against chip mount error (Only when an optional pick-up sensor is available) At the mount state check screen, the head camera checks the moun…

Page 3-36
444C-E-OMA03-A01-01
444C-619TE
Others
3-6-7 Nozzle Clogging Error
If the clogging of nozzle or the like is detected upon automatic operation, the message appears
and the operation aborts.
• In this case, the chip may be adhered to the
nozzle. Press OK to return to the main menu.
• Turn OFF the servo switch.
Check and clean the tip of the nozzle.
Turn ON the servo swith.
• Refer to the vacuum-sensor values at the
output check screen under the machine
adjustment screen.
3-6-8 Machine Adjustment Screen
When “Vacuum Sensor check” in the option configuration is set to ON, the vacuum-sensor values
are displayed on the output check screen under the machine adjustment screen.
The vacuum-pump-ON state and the air-blow-
ON state can be converted into numbers.
∗ Please note that the sensor values are subject to change without notice for improvements be
cause these are reference values.
sutatspmuP sutatsevlaV .oNelzzoN )ecnerefeR(eulavrosneS )ecnerefeR(gniggolcelzzoN
NOpmupmuucaVNOmuucaV
502002otesolC571
011512otesolC002
511522otesolC002
eromro021032otesolC002
Sensor values
Reference sensor values

Page 3-37
FUNCTIONS
3
Others
444C-E-OMA03-A01-01
3-6-9 Recovery mount function against chip mount error (Only
when an optional pick-up sensor is available)
At the mount state check screen, the head camera checks the mount state. Then you can select
whether or not to recovery-mount the mount-error components.
1. Selection whether or not to use the recovery mount function
• When the item “Chip mount error recovery”
on the option configuration screen is set to
“Use (1),” mount-error components can be
recovery-mounted automatically. When it is
set to “Unuse (0),” mount-error compo-
nents are not recovery-mounted because
they are considered to have already been
mounted.
• Set “Chip mount error recovery” to ‘1’ (Use).
To continue conventional operation, set it to ‘0’
(Unuse).
2. When “Chip mount error recovery” is set to “Use (1)”
• If a chip-mount error occurs during operation,
the mount state check screen displays.
When you wish to check the mount state of the
mount-error components, press Yes.
• Pressing Yes displays the mount state check
screen.
Pressing No returns the screen to the immedi-
ate-stop screen, and recovery-mounts the
mount-error components at the time when
production resumes.

Page 3-38
Others
444C-E-OMA03-A01-01
Displays the mount state check screen.
The sequence numbers and error types of all
the mount-error components are displayed.
• Check mount-error components, and mark the
mount-OK ones with “End.”
The detailed information of the cursor-selected
mount error is displayed at the upper right of
the screen.
When you wish to check the mount state of the
mount-error components, select the desired
SEQ using arrow buttons ( ↑ and ↓ ), and
then press
UNLOCK
+ CheckPosMove button.
The head camera travels to the mount position
of the mount-error component.
Unless the camera has traveled to the mount
position of the cursor-selected component, the
image is not displayed.
Adjustment of the head-camera lamp
The lighting values of the head camera can be
adjusted by pressing the increase and de-
crease buttons ( +1 and -1 ) of lamp 1 and
lamp 2.
Pressing LmpRate button toggles the lamp
adjusting rate between “10” and “1.”
Setting and Release of the mounted
Pressing MountEnd set releases “End” setting
if it is set in the cursor-selected row, or sets
“End” if it is not set.
The mount-error component marked with “End”
is not recovery-mounted when operation is
resumed.
The mount-error component that is not marked
with “End” is recovery-mounted when operation
is resumed.
Exit of mount state check screen
Pressing key displays the following
confirmation screen over the mount state
check screen.
Pressing Yes returns the screen to the
immediate-stop screen. Pressing No remains
the mount state check screen.
1
2
3
4
5
6
444C-EOp-DmMsc-002