Head Reconfiguration Kits 2 Assemb ly Instructions - SIPLACE X-Series Head Reconfiguration Kits 07/2010 Edition 157 : Remove the hoses from the distribu tor and the placement head. 2 2 2 Pneumatic hoses for machines up t…

2 Assembly Instructions - SIPLACE X-Series Head Reconfiguration Kits Head Reconfiguration Kits
07/2010 Edition
156
2.8.1 Removing the nozzle changer
: To remove the nozzle changer, please read the assembly instructions for the X series nozzle
changer (item no.:00194482-).
2
Risk of a head crash: Always run the placement heads with the appropriate nozzle changer. The
wrong nozzle changer causes a risk of a head crash. 2
2
2
On the subject of the reject bin sensor, also read the
assembly instructions for the reject bin sensor, SIPLACE HF series / X series
(item no.:00194550-). 2
2
2.8.2 Removing the C&P 6/12 placement head
2
Wear an ESD armband for the whole time you are working on the placement head and servos. 2
2
2
2
Remove the axis cards and servo cards.
Please note the overviews in the appendix Chapter 2.14.1 or Chapter 2.14.2. 2
2
2

Head Reconfiguration Kits 2 Assembly Instructions - SIPLACE X-Series Head Reconfiguration Kits
07/2010 Edition
157
: Remove the hoses from the distributor and the placement head.
2
2
2
Pneumatic hoses for
machines up to serial
no. B-078
C&P 6/12 vacuum hoses
for machines from serial
no. B-079

2 Assembly Instructions - SIPLACE X-Series Head Reconfiguration Kits Head Reconfiguration Kits
07/2010 Edition
158
: Remove the cooling air hose and the plug on the silencer.
2
: Remove the plug on the silencer.
2