00194474-0702_AI_HeadReconfig_X_605_DE+EN.pdf - 第241页

Head Reconfiguration Kits 2 Assemb ly Instructions - SIPLACE X-Series Head Reconfiguration Kits 07/2010 Edition 241 2 : Attach all of the compr essed air hoses. 2 2 Plug QSC-6H Item no . 00337891- Plug QSC-4H Item no . 0…

100%1 / 276
2 Assembly Instructions - SIPLACE X-Series Head Reconfiguration Kits Head Reconfiguration Kits
07/2010 Edition
240
2.13.6 Connections on the compressed air distributor
There are currently two different pneumatic distributors available depending on the cable and
hose carrier installed:
Use the old cable and hose carrier on CFK gantries 02 and 04 for the old pneumatic distributor
and
the new pneumatic distributor for the "CFK 06 gantry, new cable and hose carrier". These new
distributors are prepared for the vacuum pump on the C&P 20 head option.
2
Gantries CFK 02 and CFK 04
Gantry CFK 06
Pneumatic distributor back
Input:
7x pneumatic hose (PK6)
2x pneumatic hose
vacuum pump option (PK10)
Pneumatic distributor front
Output:
C+P 20 head
Pneumatic distributor back
Input:
7x pneumatic hose
Pneumatic distributor front
Output:
C+P 20 head
Return cylinder
Pressure
control valve
Holding
circuit
Holding
circuit
Return
cylinder
Pressure
control valve
Head Reconfiguration Kits 2 Assembly Instructions - SIPLACE X-Series Head Reconfiguration Kits
07/2010 Edition
241
2
: Attach all of the compressed air hoses.
2
2
Plug QSC-6H Item no. 00337891-
Plug QSC-4H Item no. 00330249-
Plug QSC-8H Item no. 03010908-
Plug QSC-10H Item no. 00324874-
Plug QSC-12H Item no. 03015210-
Attach compressed
air hoses
2 Assembly Instructions - SIPLACE X-Series Head Reconfiguration Kits Head Reconfiguration Kits
07/2010 Edition
242
: Connect the two ribbon cables.
2
: Switch the placement machine on at the main switch.
: Plug a USB stick or another suitable storage medium into the USB slot on the station computer.
2
: Save the machine data from the storage medium to the station computer.
Connect the
ribbon cables
USB stick