00194474-0702_AI_HeadReconfig_X_605_DE+EN.pdf - 第242页

2 Assembly Instructions - SIPLACE X-Series Head Reconfiguration Kits Head Reconfiguration Kits 07/2010 Edition 242 : Connect the two ribb on cables. 2 : Switch the placement mach ine on at the main switch. : Plug a USB s…

100%1 / 276
Head Reconfiguration Kits 2 Assembly Instructions - SIPLACE X-Series Head Reconfiguration Kits
07/2010 Edition
241
2
: Attach all of the compressed air hoses.
2
2
Plug QSC-6H Item no. 00337891-
Plug QSC-4H Item no. 00330249-
Plug QSC-8H Item no. 03010908-
Plug QSC-10H Item no. 00324874-
Plug QSC-12H Item no. 03015210-
Attach compressed
air hoses
2 Assembly Instructions - SIPLACE X-Series Head Reconfiguration Kits Head Reconfiguration Kits
07/2010 Edition
242
: Connect the two ribbon cables.
2
: Switch the placement machine on at the main switch.
: Plug a USB stick or another suitable storage medium into the USB slot on the station computer.
2
: Save the machine data from the storage medium to the station computer.
Connect the
ribbon cables
USB stick
Head Reconfiguration Kits 2 Assembly Instructions - SIPLACE X-Series Head Reconfiguration Kits
07/2010 Edition
243
2.13.7 Setting the DIP switches on the vision control unit
The vision control unit should generally be removed for configuration of the C&P 20 head in a
placement area. This is only needed for configuration with a TwinHead. TwinHead and C&P 20 is
not allowed in a placement area. 2
: The associated DIP switches on the vision control unit should be set to OFF according to the
installation location of the C&P placement heads:
Placement area 1: all MD-DIP switches at OFF.
Placement area 2: all SD-DIP switches at OFF.
The vision control unit for placement area 1 is located in the main distributor (location 4). 2
The vision control unit for placement area 2 is located in the main distributor (location 2). 2
2
2
2
If there is no TwinHead installed in the same placement area, you can remove the corresponding
vision controller in the sub or main distributor. C&P heads do not require a vision controller. 2
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF