00194474-0702_AI_HeadReconfig_X_605_DE+EN.pdf - 第185页
Head Reconfiguration Kits 2 Assemb ly Instructions - SIPLACE X-Series Head Reconfiguration Kits 07/2010 Edition 185 : Fit the component camera for the DLM he ad ( 4 screws DIN912 M4x10 - A2, item no. 00313069-). : Plug i…

2 Assembly Instructions - SIPLACE X-Series Head Reconfiguration Kits Head Reconfiguration Kits
07/2010 Edition
184
: Fit the strain relief using the three screws on the left (see photograph above).
2
2
2
The two right-hand screws must be removed - they are not needed. 2
2
: Set the star resolution switch to 25.
The switch can be found underneath the placement head.
2
: Fit the placement head and fix in place with four screws.
Make sure that you use screws of the right length and observe the correct torque:
DIN912 M4x18 - 8.8 (item no. 00095023-), tightening torque: 2.7 Nm.
With screws two and three, you should first remove one sleeve to make the screws more ac-
cessible.

Head Reconfiguration Kits 2 Assembly Instructions - SIPLACE X-Series Head Reconfiguration Kits
07/2010 Edition
185
: Fit the component camera for the DLM head ( 4 screws DIN912 M4x10 - A2, item no.
00313069-).
: Plug in the connectors for the DP axis.
2
: Plug in the two connectors.
2
: Clip on the strain relief pushbutton.

2 Assembly Instructions - SIPLACE X-Series Head Reconfiguration Kits Head Reconfiguration Kits
07/2010 Edition
186
: Plug the camera cable into the head interface board (see photograph).
: Plug the four ribbon cables into the step motor board. Make sure that the polarization is correct.
2
: Check the jumper settings on the C500 head interface board.
Jumper
Gantry
1
Gantry
2
Gantry
3
Gantry
4
1
0 1 0 1 Gantry ID0
2
0 0 1 1 Gantry ID1
3
1 1 1 1 120 Ohm CAN terminating resistor
4
0 0 0 0 Boot
5
0 0 0 0 Reset
6
0 0 0 0 CAN ID0
7
0 0 0 0 CAN ID1
8
0 0 0 0 Write protect deactivated
Component camera cable