00194474-0702_AI_HeadReconfig_X_605_DE+EN.pdf - 第177页

Head Reconfiguration Kits 2 Assemb ly Instructions - SIPLACE X-Series Head Reconfiguration Kits 07/2010 Edition 177 : Pull out all of the compressed air hoses. 2 2 : Loosen the clip and disconnect the plug for the compon…

100%1 / 276
2 Assembly Instructions - SIPLACE X-Series Head Reconfiguration Kits Head Reconfiguration Kits
07/2010 Edition
176
2.10.4 Removing the C&P20 placement head
2
Wear an ESD armband for the whole time you are working on the placement head and servos. 2
2
2
2
Remove the axis cards and servo cards.
Please note the overviews in the appendix Chapter 2.14.1 or Chapter 2.14.2. 2
2
2
The conversion is easiest to carry out from locations 2 and 4. 2
2
2
: Disconnect the two ribbon cables.
2
Remove
ribbon cable
Head Reconfiguration Kits 2 Assembly Instructions - SIPLACE X-Series Head Reconfiguration Kits
07/2010 Edition
177
: Pull out all of the compressed air hoses.
2
2
: Loosen the clip and disconnect the plug for the component camera.
2
2
2
Pull out the
compressed air hoses
Open the clip
Remove the plug
2 Assembly Instructions - SIPLACE X-Series Head Reconfiguration Kits Head Reconfiguration Kits
07/2010 Edition
178
: Loosen the two screws on the compressed air regulating valve.
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Loosen screw
Loosen and remove screw