00194474-0702_AI_HeadReconfig_X_605_DE+EN.pdf - 第187页

Head Reconfiguration Kits 2 Assemb ly Instructions - SIPLACE X-Series Head Reconfiguration Kits 07/2010 Edition 187 : If problems occur with the CAN bus, measu re the resist ance between pin 7 (CAN High) and pin 2 (CAN L…

100%1 / 276
2 Assembly Instructions - SIPLACE X-Series Head Reconfiguration Kits Head Reconfiguration Kits
07/2010 Edition
186
: Plug the camera cable into the head interface board (see photograph).
: Plug the four ribbon cables into the step motor board. Make sure that the polarization is correct.
2
: Check the jumper settings on the C500 head interface board.
Jumper
Gantry
1
Gantry
2
Gantry
3
Gantry
4
1
0 1 0 1 Gantry ID0
2
0 0 1 1 Gantry ID1
3
1 1 1 1 120 Ohm CAN terminating resistor
4
0 0 0 0 Boot
5
0 0 0 0 Reset
6
0 0 0 0 CAN ID0
7
0 0 0 0 CAN ID1
8
0 0 0 0 Write protect deactivated
Component camera cable
Head Reconfiguration Kits 2 Assembly Instructions - SIPLACE X-Series Head Reconfiguration Kits
07/2010 Edition
187
: If problems occur with the CAN bus, measure the resistance between pin 7 (CAN High) and
pin 2 (CAN Low). It should be 60 Ohm.
2
: Fit the cap (type D Di8.0 H15 flexible PVC, item no. 03006728-) on the exhaust air damper.
Jumper
position
2 Assembly Instructions - SIPLACE X-Series Head Reconfiguration Kits Head Reconfiguration Kits
07/2010 Edition
188
: Connect the top and bottom hoses.
2.11.3 Connections on the compressed air distributor
There are currently two different pneumatic distributors available depending on the cable and
hose carrier installed:
Use the old cable and hose carrier on CFK gantries 02 and 04 for the old pneumatic distributor
and
the new pneumatic distributor for the "CFK 06 gantry, new cable and hose carrier". These new
distributors are prepared for the vacuum pump on the C&P 20 head option.