182050 User manual.pdf - 第120页
semi automatic (552 50( 66$*(6 (552 50( 66$*( /,67 ,1* 3.4 User Manual Software Version 0 7SP02 Comma nd T imed Out (Camera Axe s) This er ror repor ts tha t the camera has fail ed to mo ve to the demande d position w…

semi automatic
(55250(66$*(6
(55250(66$*(/,67,1*
Software Version 07SP02 User Manual 3.3
ERROR MESSAGE LISTING
Error Message Interpretation
Alignment Out of Range This indicates that the actuator positions required to achieve a satisfactory
alignment are not attainable.
Alignment Close to Limit/Out of Range Actuator limit exceeded.
Board Detected At Board Stop, Print
Terminated.
With the machine running in any mode, this error reports that the board stop
sensor has been activated out of sequence.
Possible causes are:
Board already loaded into the machine.
Sensor is detecting tooling.
Sensor is faulty.
Board Fiducial Not Found This error reports that the vision system has been unable to locate the board
fiducial.
Board Not Over Input Sensor This error reports a machine has started without a board on the rails. The user
has ignored the message to place a board on the rails and selects continue on
the machine.
Board On Rails, Remove and Continue This error reports that a board has been sensed on the rails during one of the
following operations:
Initialization
Loading a new board file
Entering the rail system in diagnostics.
Board Stop Not Lowered This error reports that the board stop is up and has not lowered within the time-
out period of 3 seconds. The possible causes are: Board stop sensor - enter
Diagnostics and check the sensor changes state.
Air pressure failure to the board stop.
Board Stop Not Retracted This error reports that the board stop is down and has not retracted within the
time-out period of 3 seconds. A possible cause is:
Board stop sensor - enter Diagnostics, Digital Inputs and check the sensor
changes state.
Board Stop Stuck This error reports that the board stop, which is housed in the camera assembly
has failed to lower or retract.
Board Stuck in Rails This error reports that the board has failed to either reach the board stop or exit
the machine after being printed.
Camera X Axis Error This error reports that the camera carriage has failed to reach its home position
in the X axis.
Camera Y Axis Error This error reports that the camera carriage has failed to reach its home position
in the Y axis.
Command Timed Out
(Belt Motors)
This error reports if a board on the rails, fails to reach the board stop after
leaving the board at left sensor or return to the board at left sensor after the
print cycle, within the time period. Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
Board jammed on the rails.
NextMove card faulty.

semi automatic
(55250(66$*(6
(55250(66$*(/,67,1*
3.4 User Manual Software Version 07SP02
Command Timed Out
(Camera Axes)
This error reports that the camera has failed to move to the demanded position
within the time period. This error applies to both the X and Y camera axis.
Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
NextMove card faulty.
Command Timed Out
(Paste Dispense Carriage)
This error reports that the paste dispense carriage has failed to move to the
demanded position within the time period. Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
NextMove card faulty.
Command Timed out
(Print Carriage)
This error reports that the print carriage has failed to move to the demanded
position within the time period. Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
NextMove card faulty.
Command Timed Out
(ProFlow)
This error reports that the proflow unit has failed to move to the demanded
position within the time period. Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
NextMove card faulty.
Command Timed Out
(Rail System)
This error reports that the moving rail has failed to move to the demanded
position within the time period. Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
NextMove card faulty.
Command Timed Out
(Screen Actuators)
This error reports that the actuator has failed to move to the demanded position
within the time period. Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
NextMove card faulty.
Command Timed Out
(Front/Rear Squeegee)
This error reports that the front/rear squeegee has failed to move to the
demanded position within the time period. Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
NextMove card faulty.
Failed to Determine Tooling Deviation This error reports that while monitoring the tooling deviation, the number of
samples (pressure variations) during the print stroke was less than 2 or the
minimum value was zero. This error message is only valid where tooling
deviation is authorized and enabled.
Check tooling support is sufficient.
Check underside components are clear of tooling.
Front Squeegee Error This error reports that the front squeegee has failed to reach its fully up position.
Error Message Interpretation

semi automatic
(55250(66$*(6
(55250(66$*(/,67,1*
Software Version 07SP02 User Manual 3.5
Front Squeegee Pressure Error When this error is detected a new window displays the set pressure reading
and the actual pressure reading.
File Error This message appears if there is an error writing or reading a machine file.
Have All Tooling Pins Been Removed? This message appears for the user to confirm that all magnetic tooling pins
have been removed.
Invalid Calibration Data. Recalibrate
ProFlow Heights
This error reports that the ProFlow calibration data is corrupt or invalid.
Invalid Calibration Data. Recalibrate
Squeegee Heights
This error reports that the squeegee calibration data is corrupt or invalid.
Lid Bolt Fault This indicates that the lid bolt has failed to either open or close.
Paste Carriage Error This error reports that the paste carriage has failed to reach its home position.
Paste Cartridge Tilt Error This error reports that the paste cartridge mechanism has failed to either make
its up or down limit switches.
Pneumatic Power Down This error message reports that the pneumatic supply is either too low or has
been disconnected.
Position Error (Camera) This error reports that the cameras actual position is not within the tolerance of
1% of the designated position.
Position Error (Print Carriage) This error reports the print carriage actual position is not within tolerance of its
designated position.
Position Error (Rising Table) This error reports that the rising table has failed to reach its home position.
Print Carriage Error This error reports that the print carriage has failed to move.
Proflow at Movement Limit This error reports when the proflow reaches set limits whilst using jog buttons
in Diagnostics, Drive System Using Jog Buttons.
Rail Lifted Error, Check Tooling This error reports that either the left rail lifted sensor or the right rail lifted sensor
are out of their home positions when any of the following moves are taking
place:
Alignment of the screen
Board stop moving into position
Initialization of the machine
Possible causes are:
A misfed board
Tooling/object on the rising table striking the underside of the rails
Rear Squeegee Error This error reports that the rear squeegee failed to reach its fully up position.
Rear Squeegee Pressure Error When this error is detected a new window displays the set pressure reading
and the actual pressure reading.
Rising Table Error This error reports that the rising table has either failed to reach its fully down
position or that when attempting to reach the required height during the
machine cycle did not achieve the positional accuracy.
Rising Table Out of Position This error reports that either; the camera axes are not at the home position
when the rising table is to be lifted, or the rising table is at a height greater than
vision height by 1mm.
Screen/Board Fiducial Not Found This error reports that the vision system has been unable to locate the screen/
board fiducial (n). Possible causes are:
Incorrect board file for the product being run.
Incorrect board loaded.
Correct board loaded the wrong way up.
Error Message Interpretation