semi automatic ',$*126 7,&6 5$,/6<67 (0 4.18 User Manual Software Ve rsion 07SP02 Home Rail Wid th Select ing this diagnostic function dr ives the ra il wid th motor to it s home posit ion as determined by i…

100%1 / 266
semi automatic
',$*1267,&6
5$,/6<67(0
Software Version 07SP02 User Manual 4.17
RAIL SYSTEM Selecting this diagnostics module opens the following window:
The menu bar changes to the following:
Next / Previous keys move the highlight bar up and down the list of selectable
diagnostic functions.
Run Diagnost activates the diagnostic function, as selected by the highlight
bar.
Exit returns operation to the module diagnostics page.
Adjust opens the following window:
The menu bar changes to the following:
Next / Previous keys move the highlight bar up and down the list of diagnostic
parameters.
Incr. / Decr. keys change the value of the selected diagnostic parameter.
Exit returns operation to the rail system diagnostics page.
NOTE
These parameters are used in diagnostics only and have no affect on the
product board file.
Board Stop In Position
Board at Stop
Board at Left
OFF
OFF
Home Rail Width
Drive Rail To Board Width
Drive Rail Width Using Two Button Control
Drive Belts Using Two Button Control
Belt Speed Calibration
Toggle Board Clamp
Toggle Board Stop
Cycle Board On Belts
Cycle Board Clamp
Cycle Rails
Rail System Diagnostics
OFF
OFF
OFF
Run
Diagnost
Adjust Next Previous Exit
Rail System Test Parameters
BOARD WIDTH
CYCLE COUNT
250.0
50
mm
Cycles
Next Previous Incr. Decr. Exit
semi automatic
',$*1267,&6
5$,/6<67(0
4.18 User Manual Software Version 07SP02
Home Rail Width Selecting this diagnostic function drives the rail width motor to its home position
as determined by its home sensor.
Drive Rail to Board
Width
Selecting this diagnostic function drives the rail width motor to the width set by
the board width parameter.
Drive Rail Width
Using Two Button
Control
Selecting this diagnostic function drives the rail width motor using the jog
buttons. The right jog button drives the rail width motor forward at slow speed
and the left jog button drives it to the rear, stopping immediately the button is
released.
Drive Belts Using
Two Button
Control
Selecting this diagnostic function drives the belt motors using the jog buttons.
The right Jog button drives the belt motors to the right and the left Jog button
drives the belt motors to the left, stopping immediately the button is released.
Belt Speed
Calibration
Selecting this diagnostic function enables the belt speed calibration to be
carried out. For information on the belt speed calibration procedure see the
Technical Reference manual, Rail System chapter.
Toggle Board
Clamp
Selecting this diagnostic function alternately energizes and de-energizes the
board clamp, displaying On when energized and Off when de-energized.
Toggle Board Stop Selecting this diagnostic function alternately lowers and raises the board stop
housed in the camera assembly, displaying On when lowered and Off when
raised.
Cycle Board on
Belts
Selecting this diagnostic function starts a continuous cycle of driving the belts
to the right, until a board reaches the camera board stop, dwelling for 2 seconds
and driving the belts to the left, until a board reaches the board at left sensor,
dwelling for 2 seconds and repeating the cycle, until stop is pressed or the set
cycle count is reached.
Cycle Board Clamp Selecting this diagnostic function starts a continuous cycle of clamping and
unclamping the board clamps. Cycling Clamps.... is displayed in the message
prompt box.
Cycle Rails Selecting this diagnostic function drives the moveable rail from the home
position to the minimum board width and back to the home position. Cycling
Rails.... is displayed in the message prompt box.
Board Stop in
Position
This diagnostic function continuously displays the status of the board stop
lowered sensor.
Board at Stop This diagnostic function continuously displays the status of the board at stop
sensor.
Board at Left This diagnostic function continuously displays the status of the board at left
sensor. On is displayed if a board is detected on the rails at the left of the
machine.
semi automatic
',$*1267,&6
5$,/6<67(0
Software Version 07SP02 User Manual 4.19
Cycle Count This diagnostic function displays the amount of cycles done and the amount of
cycles to go to complete the cycle count.