182050 User manual.pdf - 第204页

semi automatic ',163(&7,21 0(183$5$ 0(7(5 6 7.30 User Manual Software Ve rsion 07SP02 MENU P ARAMETERS 2D Inspect Rate This p arameter s ets the number of pr int cycles between inspec tion cycles, with zero i…

100%1 / 266
semi automatic
',163(&7,21
237,216$)7(5$1,163(&7,21$/$50
Software Version 07SP02 User Manual 7.29
New Pre-images Selecting this option initiates a pre-print inspection on the next print cycle to
capture the new pre-images. The message New pre-images will be col-
lected next print cycle is displayed.
NOTE
The New Pre-image button is only available if pre-image is set to 1.
Edit Site Selecting this option opens the site parameters window, allowing adjustment of
the site specific parameters.
Inspect Site Selecting this option opens the inspection results window and displays the
following menu:
Selecting Next or Previous moves the highlight up and down the list of site
pads.
Selecting Auto Scale automatically adjusts the paste scaling value for the
current site, to cause the value of paste present, on the pad currently selected
in the inspection result list, to be reported as 100%. This is used where the site
pad causing the alarm is actually a good print.
Reject Selecting this option clears the alarm panel and the board is fed to the output
end of the rail system and held there.
Auto
Scale
Next Previous Exit
semi automatic
',163(&7,21
0(183$5$0(7(56
7.30 User Manual Software Version 07SP02
MENU PARAMETERS
2D Inspect Rate This parameter sets the number of print cycles between inspection cycles, with
zero indicating no inspection.
Board Inspect Type This parameter sets the type of inspection to be learnt:
Pre-image This parameter sets when a pre-image is taken. The options are:
Min Sites/Cycle This parameter sets the number of sites to inspect every cycle.
Warning Limit This parameter determines how many consecutive warnings on the same site
constitute an alarm.
Low Paste Action This parameter sets the action performed on a low paste alarm. The options
are:
No. Sites This parameter displays the total number of sites.
Site Name The unique name given to a site for identification. The name can have a
maximum of 20 characters.
Site Priority This parameter determines the priority of a site. Where the site is part of a
device, the value applies to the whole device. The options are:
Minimum Maximum Increments
01001
None Basic
One - First Board Only Every - Every Board
Minimum Maximum Increments
Number of Every Cycle sites plus one, ie at least
one general site must be inspected
Total number of sites 1
Minimum Maximum Increments
1201
Manual Re-print
Minimum Maximum Increments
010001
Not Inspected General Every Cycle
semi automatic
',163(&7,21
0(183$5$0(7(56
Software Version 07SP02 User Manual 7.31
NOTE
If the machine inspection page is set to GUI 2Di, all displayed sites are colour
coded, depending on their priority setting, (following table refers):
Limit Set ID The unique name given to a set of limits which can be applied to any site. This
enables different sites to be inspected according to different limits. The name
can have a maximum of 20 characters. A maximum of 14 limit sets can be
created.
Paste Scaling This parameter enables adjustment of the paste scaling value for the current
site, to cause the value of paste present on the pad, currently selected in the
inspection list, to be reported as 100%. This parameter is used in conjunction
with the Auto Scale function.
Site X Coord The coordinate of a site taken from the front left corner of the board, in the X
direction.
Site Y Coord The coordinate of a site taken from the front left corner of the board, in the Y
direction.
Site Width The width of the site to be inspected.
Site Height The height of the site to be inspected.
Site Priority Display Colour
Every Cycle
Green
General
Yellow
Not Inspected
Blue
Minimum Maximum Increments
0.01 2.00 0.01
Minimum Maximum Increments
0.0mm Board Length 0.1mm
Minimum Maximum Increments
0.0mm Board Width 0.1mm
Minimum Maximum Increments
0.5mm 4.0mm 0.01mm
Minimum Maximum Increments
0.5mm 6.5mm 0.01mm