182050 User manual.pdf - 第182页

semi automatic ',163(&7,21 02'8/(29( 59,(: 7.8 User Manual Software Version 0 7SP02 If no image files are avai lable, the di splay default s to a st andard board size represent ation of the product file …

100%1 / 266
semi automatic
',163(&7,21
02'8/(29(59,(:
Software Version 07SP02 User Manual 7.7
Graphical User Interface (GUI)
2D Inspection utilizes a Graphical User Interface (GUI) allowing inspection sites
to be set up quickly and easily.
The 2Di GUI screen is displayed when Inspect Setup is selected on the menu
bar. The GUI provides the user with the following functions:
A graphical representation of the board to be set up.
Site Priority colour coding.
Operations Buttons.
List of inspection devices and sites.
List of programmed site parameters.
Current X and Y mouse coordinates.
Vision window of board and stencil.
Camera view adjustable using vision window scroll bars (when available).
NOTE
Refer to GUI 2Di Interface figure and table further in this section.
Representation of
Board
Two types of board image files are available for displaying the product on the
GUI board representation screen:
Bitmap file (.bmp)
Extended Gerber file data (.gbx)
To display the board representation in bitmap or gerber file format, the relevant
.bmp/.gbx information must be pre-loaded into the machine PC. The image is
scaled to fit the representation of the board on display, (example of gerber file
import shown below).
semi automatic
',163(&7,21
02'8/(29(59,(:
7.8 User Manual Software Version 07SP02
If no image files are available, the display defaults to a standard board size
representation of the product file being printed.
By utilizing the mouse control, any area of the board representation selected by
the user roughly positions the camera to this area. Fine positioning is then
carried out by adjusting the X and Y scroll bars in the vision window. Existing
sites can easily be selected and adjusted using the mouse control.
NOTE
The vision window X and Y scroll bars are displayed only when movement of
the camera is allowed within GUI.
Site Colour Coding Sites displayed on the board representation are coloured according to their site
priority parameter setting, as detailed in the following table.
NOTE
The current selected site is displayed in black.
Operations Buttons The five operations buttons are sited underneath the representation of the
board and are used to perform functions on the board. These are:
Load Image File - allows user to browse and select .bmp/.gbx image file.
Unload Image File - allows user to unload the current .bmp/.gbx image file.
Zoom In - zooms in to sites on the board representation.
Zoom Out - zooms out from sites on the board representation.
Fiducial Positions - show/hides board fiducial positions.
List of Devices and
Sites
The list of devices and sites created are displayed in an expandable and
collapsible form.
By selecting a site in the list, the camera moves to that site position and the
board representation site is highlighted with a camera position icon.
By selecting a device in the list, the device list automatically expands to show
all sites within that device. The first site within the list is selected and the camera
moves to that site position, the board representation site is highlighted with a
camera position icon.
NOTE
In this instance a device itself can never be selected.
Site Parameters The site parameters window enables the user to view the editable parameters
for the current site selected.
NOTE
The parameters in this display are view only.
X and Y Site
Coordinates
The X and Y site coordinates display is the current position of the mouse pointer
on the board representation.
Site Priority Display Colour
Every Cycle
Green
General
Yellow
Not Inspected
Blue
semi automatic
',163(&7,21
02'8/(29(59,(:
Software Version 07SP02 User Manual 7.9
Vision Window The video monitor displays what the camera views, (both board and stencil). A
Region of Interest (ROI) box (red outlined), representing the current boundary
of the site is superimposed on both stencil and board displays.
When movement of the camera is allowed within GUI, scroll bars are displayed
in the vision window to enable fine positioning of the camera unit during site
setup.
Figure 7-5 GUI 2Di Interface (Bitmap File Representation)
Item Description Item Description
1 Board Representation (.bmp or .gbx image file) 9 Vision Window Y Scroll Bar (when available)
2 Inspection Site 10 Vision Window X Scroll Bar (when available)
3 Camera Position Icon 11 Show / Hide Fiducial Positions
4 Inspection Site Parameters 12 Zoom Out on Board Representation
5 Site List 13 Zoom In on Board Representation
6 Site Priority Guide 14 Unload .bmp or .gbx Image file
7 Site Y Coordinates (current mouse position) 15 Load .bmp or .gbx Image file
8 Site X Coordinates (current mouse position)