182050 User manual.pdf - 第94页
semi automatic 0$&+,1( 352*5$ 00,1* 0(183$5$ 0(7(5 6 1.84 User Manual Software Ve rsion 07SP02 ProFlow Cassette This parameter set s the size of t he transfer head used by the ProF low unit. Size may be one of the …

semi automatic
0$&+,1(352*5$00,1*
0(183$5$0(7(56
Software Version 07SP02 User Manual 1.83
Clean After The Automatic screen clean after downtime process chosen in the above menu
parameter is carried out after a countdown of the number of minutes set in this
parameter.
Dry Clean Speed This parameter sets the speed of the screen clean dry wipe for optimization.
Wet Clean Speed This parameter sets the speed of the screen clean wet wipe for optimization.
Vac Clean Speed This parameter sets the speed of the screen clean vacuum for optimization.
Front Start Offset
(Blue USC)
This parameter determines the distance from the front edge of the board that
the cleaning stroke must start.
Front Start Offset
(Vortex USC)
This parameter determines the distance from the front edge of the board that
the cleaning stroke must finish.
Rear Start Offset
(Blue USC)
This parameter determines the distance from the rear edge of the board that
cleaning must complete.
Rear Start Offset
(Vortex USC)
This parameter determines the distance from the rear edge of the board that
cleaning must start.
Minimum Maximum Increment
5.0 mins 120.0 mins 1.0 min
Minimum Maximum Increment
10.0mm/sec 120.0mm/sec 1.0mm/sec steps
Minimum Maximum Increment
10.0mm/sec 100.0mm/sec 1.0mm/sec steps
Minimum Maximum Increment
10.0mm/sec 100.0mm/sec 1.0mm/sec steps
Minimum Maximum Increment
0.0mm 60.0mm 1.0mm
Minimum Maximum Increment Default
-60.0mm 60.0mm 1.0mm 30.0mm
Minimum Maximum Increment
0.0mm 60.0mm 1.0mm
Minimum Maximum Increment Default
-60.0mm 60.0mm 1.0mm 30.0mm

semi automatic
0$&+,1(352*5$00,1*
0(183$5$0(7(56
1.84 User Manual Software Version 07SP02
ProFlow Cassette This parameter sets the size of the transfer head used by the ProFlow unit. Size
may be one of the following:
NOTE
For 350mm and 450mm transfer heads, set to 400mm and 500mm respectively.
ProFlow System
Pressure
This is the amount of print pressure (downward force) applied onto the stencil
by the ProFlow unit.
Board 1 Fiducial
Type
This determines the type of model to be used for this fiducial. Options are:
Board 2 Fiducial
Type
This determines the type of model to be used for this fiducial. Options are:
Size
300.0mm
400.0mm
500.0mm
Minimum Maximum Increment Default
0.0Kg 20.0Kg 0.2Kg 0.0Kg
Model Option Note
Circle
See vision system
Rectangle
Diamond
Triangle
Double Square
Cross
Video Model
Model Option Note
Circle
See vision system
Rectangle
Diamond
Triangle
Double Square
Cross
Video Model

semi automatic
0$&+,1(352*5$00,1*
0(183$5$0(7(56
Software Version 07SP02 User Manual 1.85
Screen 1 Fiducial
Type
This determines the type of model to be used for this fiducial. Options are:
Screen 2 Fiducial
Type
This determines the type of model to be used for this fiducial. Options are:
Fiducial 1 X
Coordinate
Distance of first fiducial from the right or left hand edge of the board (configura-
tion dependent).
If the current product includes at least one inspection site, changing the value
of the parameter causes the following warning and menu bar to be displayed:
On selecting Apply the alterations to the fiducial positions become effective and
are applied to all inspection sites.
On selecting Abandon Changes the alterations to the fiducial positions are
discarded, the positions of the inspection sites remain unaltered and control is
returned to the initiating sequence.
On selecting Don’t Apply the alterations to the fiducial positions become
effective, but are not applied to the inspection sites.
Model Option Note
Circle
See vision system
Rectangle
Diamond
Triangle
Double Square
Cross
Video Model
Model Option Note
Circle
See vision system
Rectangle
Diamond
Triangle
Double Square
Cross
Video Model
Minimum Maximum Increment Default
1.0mm Board Length 0.1mm 1.0mm
Warning
From the changes made to fiducial positions
do you want a correction to be applied to
all inspection sites?
Apply
Abandon
Changes
Don’t
Apply