182050 User manual.pdf - 第121页

semi automatic (55250( 66$* (6 (55250( 66$* (/,67,1 * Software Version 07SP02 User Manual 3.5 Front Squee gee Pressure E rror When this error is detected a new window displays the set pres sure readi ng and the actual…

100%1 / 266
semi automatic
(55250(66$*(6
(55250(66$*(/,67,1*
3.4 User Manual Software Version 07SP02
Command Timed Out
(Camera Axes)
This error reports that the camera has failed to move to the demanded position
within the time period. This error applies to both the X and Y camera axis.
Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
NextMove card faulty.
Command Timed Out
(Paste Dispense Carriage)
This error reports that the paste dispense carriage has failed to move to the
demanded position within the time period. Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
NextMove card faulty.
Command Timed out
(Print Carriage)
This error reports that the print carriage has failed to move to the demanded
position within the time period. Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
NextMove card faulty.
Command Timed Out
(ProFlow)
This error reports that the proflow unit has failed to move to the demanded
position within the time period. Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
NextMove card faulty.
Command Timed Out
(Rail System)
This error reports that the moving rail has failed to move to the demanded
position within the time period. Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
NextMove card faulty.
Command Timed Out
(Screen Actuators)
This error reports that the actuator has failed to move to the demanded position
within the time period. Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
NextMove card faulty.
Command Timed Out
(Front/Rear Squeegee)
This error reports that the front/rear squeegee has failed to move to the
demanded position within the time period. Possible causes are:
Home sensor fault, if occurring during initialization.
Motor fault, if occurring during initialization.
Motor not running.
NextMove card faulty.
Failed to Determine Tooling Deviation This error reports that while monitoring the tooling deviation, the number of
samples (pressure variations) during the print stroke was less than 2 or the
minimum value was zero. This error message is only valid where tooling
deviation is authorized and enabled.
Check tooling support is sufficient.
Check underside components are clear of tooling.
Front Squeegee Error This error reports that the front squeegee has failed to reach its fully up position.
Error Message Interpretation
semi automatic
(55250(66$*(6
(55250(66$*(/,67,1*
Software Version 07SP02 User Manual 3.5
Front Squeegee Pressure Error When this error is detected a new window displays the set pressure reading
and the actual pressure reading.
File Error This message appears if there is an error writing or reading a machine file.
Have All Tooling Pins Been Removed? This message appears for the user to confirm that all magnetic tooling pins
have been removed.
Invalid Calibration Data. Recalibrate
ProFlow Heights
This error reports that the ProFlow calibration data is corrupt or invalid.
Invalid Calibration Data. Recalibrate
Squeegee Heights
This error reports that the squeegee calibration data is corrupt or invalid.
Lid Bolt Fault This indicates that the lid bolt has failed to either open or close.
Paste Carriage Error This error reports that the paste carriage has failed to reach its home position.
Paste Cartridge Tilt Error This error reports that the paste cartridge mechanism has failed to either make
its up or down limit switches.
Pneumatic Power Down This error message reports that the pneumatic supply is either too low or has
been disconnected.
Position Error (Camera) This error reports that the cameras actual position is not within the tolerance of
1% of the designated position.
Position Error (Print Carriage) This error reports the print carriage actual position is not within tolerance of its
designated position.
Position Error (Rising Table) This error reports that the rising table has failed to reach its home position.
Print Carriage Error This error reports that the print carriage has failed to move.
Proflow at Movement Limit This error reports when the proflow reaches set limits whilst using jog buttons
in Diagnostics, Drive System Using Jog Buttons.
Rail Lifted Error, Check Tooling This error reports that either the left rail lifted sensor or the right rail lifted sensor
are out of their home positions when any of the following moves are taking
place:
Alignment of the screen
Board stop moving into position
Initialization of the machine
Possible causes are:
A misfed board
Tooling/object on the rising table striking the underside of the rails
Rear Squeegee Error This error reports that the rear squeegee failed to reach its fully up position.
Rear Squeegee Pressure Error When this error is detected a new window displays the set pressure reading
and the actual pressure reading.
Rising Table Error This error reports that the rising table has either failed to reach its fully down
position or that when attempting to reach the required height during the
machine cycle did not achieve the positional accuracy.
Rising Table Out of Position This error reports that either; the camera axes are not at the home position
when the rising table is to be lifted, or the rising table is at a height greater than
vision height by 1mm.
Screen/Board Fiducial Not Found This error reports that the vision system has been unable to locate the screen/
board fiducial (n). Possible causes are:
Incorrect board file for the product being run.
Incorrect board loaded.
Correct board loaded the wrong way up.
Error Message Interpretation
semi automatic
(55250(66$*(6
(55250(66$*(/,67,1*
3.6 User Manual Software Version 07SP02
Screen Cleaner Out Of Position This error reports that the screen cleaner is out of position. Possible causes
are:
Screen Cleaner not at the home position.
Home sensor - enter Diagnostics, Digital Inputs and check the sensor changes
state.
If a screen cleaner is not fitted, check that the home sensor is not connected.
Screen Couplings Not Extended This error reports that the screen couplings have failed to extend within the 4
second time-out period.
Screen XF Error This error reports that the X forward screen actuator failed to initialize to its
central datum.
Screen XR Error This error reports that the X rear screen actuator failed to initialize to its central
datum.
Screen Y Error This error reports that the Y screen actuator failed to initialize to its central
datum.
Set Pressure %2.21f Actual Pressure
%2.21f (Front/Rear Squeegee)
This error reports if the front/rear squeegee pressure differs from the pressure
set by more than ± 1.00Kg.
System Power Down This error reports that the 24V motor power has been switched off either by the
Emergency Stop button being activated or that the removable frame access
cover has been removed.
System Suspended While Covers Open This error reports that whilst the machine was switched on, one or more of the
cover interlock switches were out of position.
Table Movement Inhibited,
Camera Not Home.
This error reports that the camera is over the table and the NextMove is sent
an instruction to move the rising table.
This Diagnostic Cannot Run
Until Proflow Is At home
This error reports if proflow is not in the home position (Print Carriage Diagnos-
tics only).
This Diagnostic Cannot Run With
Proflow Fitted
This error reports if in Print Carriage Diagnostics, Move Print Carriage to Paste
Position is selected.
Unable to Find Fiducial This error reports that the vision system is unable to locate the relevant screen
or board fiducial.
Window Error This error reports that the menu structure has failed to open correctly.
X Actuator Limit Exceeded This error reports that either X actuators are driven past its limit set during
calibration.
Y Actuator Limit Exceeded This error reports that the Y actuator is driven past its limit set during calibration.
Error Message Interpretation