182050 User manual.pdf - 第160页
semi automatic +286(.((3,1 * &23<'$7$ 6.6 User Manual Software Version 0 7SP02 COPY DA T A The Copy Data f unction allows the ope rator to copy dat a between the local hard drive, local dr ive and net work …

semi automatic
+286(.((3,1*
35,17'$7$
Software Version 07SP02 User Manual 6.5
If the Print Printer or Print File keys are pressed when Product Data is
highlighted the following window is displayed:
The menu bar changes to the following:
The Left and Right keys move between columns (if displayed).
The Up and Down keys move vertically through the files.
Exit returns to the housekeeping display without any other action.
Print Printer outputs the Product File to the local printer.
Print File outputs the Product File to the machines floppy drive, the file has a
.PRN extension.
Print Data File
Search
265TEST1
Product ID
265TEST1-
265TEST1
CALIBRA
DEFAULT
Print
Printer
Print
Data
Left Right Up Down Exit

semi automatic
+286(.((3,1*
&23<'$7$
6.6 User Manual Software Version 07SP02
COPY DATA
The Copy Data function allows the operator to copy data between the local hard
drive, local drive and network drives.
On selecting Copy Data the following window is displayed:
NOTE
Deviation Data is not available on this machine.
The menu bar changes to the following:
NOTE
Copy All is only available when product Data is highlighted.
The Up and Down keys move the cursor between the various data types.
The From Disk key allows selection of the disk to copy from, options are:
Local Drive; Floppy Drive; Network Drive.
The To Disk key allows selection of the disk to be copied to, options are:
Local Drive; Floppy Drive; Network Drive.
The Exit key returns to the previous menu.
The function of the Copy Data key depends upon the data type selected. If Test
Data, SPC Data, Config Data or Service Data are selected the files are
transferred directly from the source to the destination and no further options are
given.
NOTE
Copying Config Data copies the following files:
• CALIB.INI
•CONFIG.CFG
These files are required if the machine requires a Windows NT recovery
procedure.
Copy Data
Copy From: Local Drive
Copy To: Floppy Drive
Drive
Product Data
Test Data
SPC Data
Config File
Service Data
Deviation Data
Image Data
Copy
Data
Co py
All
Up Down
From
Disk
To
Disk
Exit

semi automatic
+286(.((3,1*
&23<'$7$
Software Version 07SP02 User Manual 6.7
The file names under each item are as follows:
If the Copy Data key is pressed when Product Data is highlighted, the message
‘Do you also want to create a copy of the inspection data?’ is displayed.
The following window is displayed:
The menu bar changes to the following:
The Yes key copies the highlighted product data file between the drives as
indicated, with all the inspection data that is associated with it. The message
‘Copying All Files Please Wait’ is displayed.
The No key copies the highlighted product data file between the drives as
indicated, without the inspection data that is associated with it. The message
‘Copying All Files Please Wait’ is displayed.
Test Data SPC Data Config Data Service Data
atest.dat readings.dek calib.ini service.dat
fiducial.dat config.cfg replen.dat
inspect.dat maint.dat
location.dat config.txt
offset.dat
test.dat
test.log
theta.dat
videoxy.dat
Copy Data File
Search
265TEST1
Product ID
265TEST1-
265TEST1
CALIBRA
DEFAULT
Yes No