00197463-03_SM_CPP_Customer_EN.pdf - 第110页

9 Intermediate distributor and vacuum sensor 9.2 Replacing Intermediate Distributors 1 and 2 110 Service Manual SIPLACE Multistar (CPP / CPP M) 02/2018 9.2.1 Intermediate distributor ZV1/CPP [03065295-xx] 03065295-02 The…

100%1 / 120
9 Intermediate distributor and vacuum sensor
9.2 Replacing Intermediate Distributors 1 and 2
Service Manual SIPLACE Multistar (CPP / CPP M) 02/2018 109
Installation
Follow the removal instructions in reverse order for further installation.
Also observe the installation instructions in the following section:
9.1 "Replacing the KE Control Board ZV2 [03073355-xx]" [}105]
Fig.184: Checking the status and function of the heads
Only when replacing ID1:
After the machine has been restarted write the cali-
bration values from the machine data to the head EE-
PROM. To do so, proceed as follows:
Click the
button.
Click the
button.
Select the head.
Click the
button.
Click on the button Write calibration data to EE-
PROM.
9 Intermediate distributor and vacuum sensor
9.2 Replacing Intermediate Distributors 1 and 2
110 Service Manual SIPLACE Multistar (CPP / CPP M) 02/2018
9.2.1 Intermediate distributor ZV1/CPP [03065295-xx]
03065295-02
The intermediate distributor 1 (ID1) establishes the
connection to the intermediate distributor 2 (ID2) and
the adapter board. In addition, various sensors and
actuators for the CPP head are directly connected
here.
1. X25 – connector to ID2
2. X24 – Z motor
3. X22 – connector Z axis encoder (track signals)
with EEPROM
4. X15 – return cylinder
5. X1 – flat ribbon cable connector to head adapter
6. X2 – flat ribbon cable connector to the head ad-
apter
7. LEDs V107 to V118 (see below)
03065295-02
LED overview
LED [03065295-02]
LED Color Status Signal name Description
V106 GN ON 15V+ +15VDC operating voltage
V107 GN ON 5V+ +5VDC operating voltage
V108 GN ON 15V- -15VDC operating voltage
V111 RD ON Z_COUNT_ERR Z axis sensor error
V112 RD ON S_COUNT_ERR Star axis sensor error
V115 GN ON 3.3V+_DP +3.3VDC DP operating voltage
V116 YE ON STATUS_PRES-
SURECONTROL-
VALVE
Status: control valve pressure OK
V117 YE ON Z_BOTTOM_LED Z_bottom sensor ON
V118 YE ON V4_OUT Return cylinder extended
9 Intermediate distributor and vacuum sensor
9.2 Replacing Intermediate Distributors 1 and 2
Service Manual SIPLACE Multistar (CPP / CPP M) 02/2018 111
9.2.2 Intermediate distributor ZV2/CPP [03052586-xx]
03052586-03
Intermediate distributor ID2
LED [03052586-03]
LED Color Status Description
V14 YE ON +24VDC_DP_switched
V17 YE ON Potential difference between GND and GND_DP
present
V18 YE ON Potential difference between GND and GND_DP
present
Dip switch S1 [03052586-03]
Switch Status Signal name Description
S1.1 OFF CAN_ID CAN_ID pressure control valve
CAN test – switch over to a cable for head CAN bus
S1.2 OFF CAN_TEST CAN bus test
CAN-ID – set to a fixed CAN ID for the pressure control
valve (for test purposes only)