00197463-03_SM_CPP_Customer_EN.pdf - 第32页

4 Component camera and component sensor 4.2 Replacing the component sensor [03037106-xx] 32 Service Manual SIPLACE Multistar (CPP / CPP M) 02/2018 4.2 Replacing the component sensor [03037106-xx] Parts, equipment and too…

100%1 / 120
4 Component camera and component sensor
4.1 Replacing the component camera [03018637‑xx]
Service Manual SIPLACE Multistar (CPP / CPP M) 02/2018 31
Installation
Follow the removal instructions in reverse order for installation. Also observe the following in-
structions:
CAUTION
Installation instructions
Make sure that you do not damage or contaminate the camera lens system.
Tighten the fourscrews fastening the component camera base with a torque of 2Nm
and the other two screws hand-tight.
Make sure that the GigE cable is run correctly (see below).
Fig.31: Fastening the GigE cable
Only heads with GigE:
Use cable ties to fasten the GigE cable to the fix-
ture(1) (if present).
4 Component camera and component sensor
4.2 Replacing the component sensor [03037106-xx]
32 Service Manual SIPLACE Multistar (CPP / CPP M) 02/2018
4.2 Replacing the component sensor [03037106-xx]
Parts, equipment and tools
CPP component sensor [03037106-xx]
Overview
Fig.32: BE sensor
1. Fastening screws for component sensor
2. Connector
3. Component sensor
As a default, each CPP head is fitted with a compo-
nent sensor in the pickup/place position.
The component sensor monitors the presence and/or
component height after pickup and before placement.
Preparation
Remove the head from the machine. For details about removing and fitting the placement
head, refer to the service manual for your machine.
fit the head on the head mount [03056231‑xx].
Removal
CAUTION
Prisms on the component sensor
Take care not to damage the component sensor prisms.
Unplug the connector from the component sensor by pressing the sides of it together slightly.
This releases the catch in the connector.
Remove the two fastening screws.
Carefully pull the connector off.
Installation
Follow the removal instructions in reverse order for installation. Also observe the following in-
structions:
CAUTION
Installation instructions
Tighten the screws fastening the component sensor with a torque of 1.45Nm.
To place components smaller than 0201, you need to calibrate the component sensor.
For more information, read section 10.3 "Calibrating the CO Sensor" [}117].
4 Component camera and component sensor
4.3 Replacing the component sensor cable [03063595-xx]
Service Manual SIPLACE Multistar (CPP / CPP M) 02/2018 33
4.3 Replacing the component sensor cable [03063595-xx]
Parts, equipment and tools
Component sensor CPP [03063595‑xx]
Overview
Fig.33: Component sensor cable
1. Plug for intermediate distributor2 (ID2)
2. Intermediate distributor 2 with KE control board
ID2 (rucksack board)
See also 9.2 "Replacing Intermediate Distributors
1 and 2" [}107]
3. Cable to component sensor
4. Connector on component sensor
Preparation
Remove the head from the machine. For details about removing and fitting the placement
head, refer to the service manual for your machine.
fit the head on the head mount [03056231‑xx].
Make sure that the component sensor protective cap is fitted.
1.1.3 "Protecting the component sensor" [}8]
Removal
Unplug the connector from the component sensor by pressing the sides of it together slightly.
This releases the catch in the connector.
Using the same procedure, unplug the connector (X21) from ID2.
Remove all relevant cable ties. You may want to mark their positions for easier exact replace-
ment later on.
Remove the cable.
Installation
Follow the removal instructions in reverse order for installation. Also observe the following in-
structions:
CAUTION
Installation instructions
Fasten the cable with cable ties.
Make sure that the cable is run correctly.