00197463-03_SM_CPP_Customer_EN.pdf - 第112页

9 Intermediate distributor and vacuum sensor 9.2 Replacing Intermediate Distributors 1 and 2 112 Service Manual SIPLACE Multistar (CPP / CPP M) 02/2018 9.2.2.1 Connector Assignment Fig.185: Connector assignment The foll…

100%1 / 120
9 Intermediate distributor and vacuum sensor
9.2 Replacing Intermediate Distributors 1 and 2
Service Manual SIPLACE Multistar (CPP / CPP M) 02/2018 111
9.2.2 Intermediate distributor ZV2/CPP [03052586-xx]
03052586-03
Intermediate distributor ID2
LED [03052586-03]
LED Color Status Description
V14 YE ON +24VDC_DP_switched
V17 YE ON Potential difference between GND and GND_DP
present
V18 YE ON Potential difference between GND and GND_DP
present
Dip switch S1 [03052586-03]
Switch Status Signal name Description
S1.1 OFF CAN_ID CAN_ID pressure control valve
CAN test – switch over to a cable for head CAN bus
S1.2 OFF CAN_TEST CAN bus test
CAN-ID – set to a fixed CAN ID for the pressure control
valve (for test purposes only)
9 Intermediate distributor and vacuum sensor
9.2 Replacing Intermediate Distributors 1 and 2
112 Service Manual SIPLACE Multistar (CPP / CPP M) 02/2018
9.2.2.1 Connector Assignment
Fig.185: Connector assignment
The following sensors and actuators for the CPP head
are connected to the intermediate distributor using
press-fit connections:
1. X21 – CO sensor
2. X19 – Vacuum sensor holding circuit
3. X29 – Energy transmission collector ring (24 V)
(CPP head before version 05)
4. X26 Energy transmission (contactless) CPP head
from version 05
5. X20 – Not used
6. X23 – Star encoder connectors (track signals)
with EEPROM, X25 star motor
7. X12 – Digital pressure control valve
8. X30 – Connector to intermediate distributor 1
9. Switch S1.1: CAN test
Switch S1.2: CAN ID
Set both switches to OFF.
10. V17/V18 – Potential display, voltage present
11. 24V – DP 24V switched
12. X31,X32 connector for the KE transmitter control
board (CPP head from version 05)
X14, X16, X16B: Test connector CAN Bus
X27, X28: FPGA test connector
 NOTICE!
Either X20, X26 or X29 is used!
.
LEDs
LED
(from left to right)
Meaning
ZU - V106 Z_bottom sensor – LED on = Z_bottom sensor activated
T1 - V113 Output FPGA
T2 - V112 Output FPGA
T3 - V111 Output FPGA
T4 - V110 Output FPGA
T5 - V109 Output FPGA
T6 - V114 Output FPGA
E1 - V107 Input FPGA
E2 - V108 Input FPGA
VAK - V11 LED on = pressure control valve not ready (5V status)
24V - V14 Operating voltage DP axes 24V
V17 Potential display – LED on = voltage present
V18 Potential display – LED on = voltage present
9 Intermediate distributor and vacuum sensor
9.3 Replacing the vacuum sensor [03036806-xx]
Service Manual SIPLACE Multistar (CPP / CPP M) 02/2018 113
Addressing the Contactless Energy Transformer
Fig.186: KE transmitter
For contactless energy transmission an additional
board is plugged onto the intermediate distributor 2.
1. X31/X32 - KE transmitter connector terminal
Description of the LEDs:
V6 – maximum current exceeded
V7 – continuous current too high
V9 – KE control switched on
V10 – error, KE transmitter switched off
The green LED V9 lights in normal operation
9.3 Replacing the vacuum sensor [03036806-xx]
Parts, equipment and tools
Fig.187: Vacuum sensor assembly for CPP [03036806-xx]
Vacuum sensor assembly for CPP [03036806-xx]
Preparation
Remove the head from the machine. For details about removing and fitting the placement
head, refer to the service manual for your machine.
fit the head on the head mount [03056231‑xx].
Make sure that the component sensor protective cap is fitted.
1.1.3 "Protecting the component sensor" [}8]