10 Calibration
10.2 Calibration Procedure
116 Service Manual SIPLACE Multistar (CPP / CPP M) 02/2018
Fig.193: Automatic Calibration
► Select Heads and cameras.
► Click on the Continue button.
Follow the instructions on the next pages:
► On the next page, select the gantries on which
the heads to be calibrated are located and then
click on the Next button.
► The next step is to check the calibration condi-
tions (nozzle, calibration tool etc.). Follow the in-
structions provided.
After this step, calibration will begin. All required inter-
mediate steps (head height etc.) will be performed
automatically.
10.2 Calibration Procedure
Fig.194: C&P calibration procedure

10 Calibration
10.3 Calibrating the CO Sensor
Service Manual SIPLACE Multistar (CPP / CPP M) 02/2018 117
10.3 Calibrating the CO Sensor
Fig.195: Calibrating the component sensor (example of
SIPLACE CPP shown)
► Switch over to the operator level Machine Ser-
vice.
► Click on the
button.
► Select the head.
► Click on the
button.
► Click on the Calibrate component sensorbu-
tton.