9 Intermediate distributor and vacuum sensor 9.3 Replacing the vacuum sensor [03036806-xx] Service Manual SIPLACE Multistar (CPP / CPP M) 02/2018 113 Addressing the Contactless Energy Transformer Fig.186: KE transmitter…

100%1 / 120
9 Intermediate distributor and vacuum sensor
9.2 Replacing Intermediate Distributors 1 and 2
112 Service Manual SIPLACE Multistar (CPP / CPP M) 02/2018
9.2.2.1 Connector Assignment
Fig.185: Connector assignment
The following sensors and actuators for the CPP head
are connected to the intermediate distributor using
press-fit connections:
1. X21 – CO sensor
2. X19 – Vacuum sensor holding circuit
3. X29 – Energy transmission collector ring (24 V)
(CPP head before version 05)
4. X26 Energy transmission (contactless) CPP head
from version 05
5. X20 – Not used
6. X23 – Star encoder connectors (track signals)
with EEPROM, X25 star motor
7. X12 – Digital pressure control valve
8. X30 – Connector to intermediate distributor 1
9. Switch S1.1: CAN test
Switch S1.2: CAN ID
Set both switches to OFF.
10. V17/V18 – Potential display, voltage present
11. 24V – DP 24V switched
12. X31,X32 connector for the KE transmitter control
board (CPP head from version 05)
X14, X16, X16B: Test connector CAN Bus
X27, X28: FPGA test connector
 NOTICE!
Either X20, X26 or X29 is used!
.
LEDs
LED
(from left to right)
Meaning
ZU - V106 Z_bottom sensor – LED on = Z_bottom sensor activated
T1 - V113 Output FPGA
T2 - V112 Output FPGA
T3 - V111 Output FPGA
T4 - V110 Output FPGA
T5 - V109 Output FPGA
T6 - V114 Output FPGA
E1 - V107 Input FPGA
E2 - V108 Input FPGA
VAK - V11 LED on = pressure control valve not ready (5V status)
24V - V14 Operating voltage DP axes 24V
V17 Potential display – LED on = voltage present
V18 Potential display – LED on = voltage present
9 Intermediate distributor and vacuum sensor
9.3 Replacing the vacuum sensor [03036806-xx]
Service Manual SIPLACE Multistar (CPP / CPP M) 02/2018 113
Addressing the Contactless Energy Transformer
Fig.186: KE transmitter
For contactless energy transmission an additional
board is plugged onto the intermediate distributor 2.
1. X31/X32 - KE transmitter connector terminal
Description of the LEDs:
V6 – maximum current exceeded
V7 – continuous current too high
V9 – KE control switched on
V10 – error, KE transmitter switched off
The green LED V9 lights in normal operation
9.3 Replacing the vacuum sensor [03036806-xx]
Parts, equipment and tools
Fig.187: Vacuum sensor assembly for CPP [03036806-xx]
Vacuum sensor assembly for CPP [03036806-xx]
Preparation
Remove the head from the machine. For details about removing and fitting the placement
head, refer to the service manual for your machine.
fit the head on the head mount [03056231‑xx].
Make sure that the component sensor protective cap is fitted.
1.1.3 "Protecting the component sensor" [}8]
9 Intermediate distributor and vacuum sensor
9.3 Replacing the vacuum sensor [03036806-xx]
114 Service Manual SIPLACE Multistar (CPP / CPP M) 02/2018
Removal
Fig.188: Cover
Turn the head over.
Remove the four screws (1) fastening the cover
(2) and remove the cover.
Fig.189: Cables and cable ties
Remove the cable ties(1).
Unthread the cable as far as the intermediate dis-
tributor2(2) and then unplug the cable.
You may want to mark the position, to make clear
assignment easier later on.
Fig.190: Vacuum sensor
Pull the hose(3) off the vacuum sensor(1).
Remove the two screws(2) fastening the vacuum
sensor.
Pull the vacuum sensor and cable under the pipe
section and out, in the direction of the arrow(4).
Installation
Follow the removal instructions in reverse order for installation.