2 Operational safety User manual SIPLACE X-Series 2.7 Residual voltages and discharge times in the machine From software version 710.0 Edition 12/2016 102 2.7.3 Machine switched off at the main power switch and disconnec…

100%1 / 416
User manual SIPLACE X-Series 2 Operational safety
From software version 710.0 Edition 12/2016 2.7 Residual voltages and discharge times in the machine
101
2.7.2 Machine switched off at the main switch, but still connected
2
2
Fig. 2.7 - 1 Power supply unit, front view
(1) Main switch (S1)
(2) Mains terminals (X95) for the power supply cable
(3) Service socket (X98)
DANGER
Lethal voltages!
Incorrect handling of the machine can therefore result in death or severe injury or consid-
erable damage to equipment.
The following components still carry potentially lethal voltages in the power supply unit,
even if the main power switch is switched off:
Mains connection terminals X94
L1, L2 and L3 of main switch S1
Service socket X98
Safety cutoff (CSB) still live for 5 minutes after switching off the main switch.
The color of all individual wires, which still carry electricity, even if the main power
switch is switched off, is orange.
(3)
(1)
(2)
2 Operational safety User manual SIPLACE X-Series
2.7 Residual voltages and discharge times in the machine From software version 710.0 Edition 12/2016
102
2.7.3 Machine switched off at the main power switch and disconnected
2
2.7.4 Compressed air conditions in the machine after switching off at the main
power switch
When the main switch is switched off or the mains supply to the machine fails, the electrically-con-
trolled main valve of the compressed air unit will close (item 1 in fig. 2.8 - 1
, page 104 ). The pres-
sure will drop to 0 MPa (0 bar) within 5 seconds.
DANGER
Lethal voltages in the power supply unit!
The power supply unit has components (capacitors) which can still conduct potentially le-
thal voltages for approx. 5 minutes, even when the machine is switched off and the mains
plug has been disconnected.
Wait at least 5 minutes before you perform work on the power supply unit.
Only ASM Assembly Systems GmbH&Co.KG service engineers or the machine
owner's service engineers, who have been trained by ASM, may perform work on the
power supply and the safety cutoff (CBS).
User manual SIPLACE X-Series 2 Operational safety
From software version 710.0 Edition 12/2016 2.8 Disabling the compressed air supply and discharging the pressure
103
2.8 Disabling the compressed air supply and discharging
the pressure
The compressed air unit is located in the sector distributor of location 1 (see fig. 4.2 - 1, page 214
). The compressed air working pressure of the machine is set to 0.50 ± 0.025 MPa (5.0 ± 0.25
bar). The position of the compressed air unit is shown at item 1 in fig. 2.8 - 1
, page 104. The supply
of compressed air to the machine can be interrupted with the shutoff valve (item 2 in fig. 2.8 - 1
,
page 104
).
Use the machine key to release the cover lock.
Lift the cover (see fig. 2.8 - 1, page 104 ).
Turn the lever of the shutoff valve (item 1 of fig. 2.8 - 1, page 104) from the vertical to the
horizontal position.
Monitor the operating pressure manometer (item 5 in fig. 2.8 - 1, page 104 ). When the ma-
chine is switched on, the pressure discharges to 0 MPa (0 bar) within 1 minute.
2
CAUTION
Interruption to compressed air supply!
When the machine is switched on, do not use the stop valve to interrupt the com-
pressed air supply for more than 30 minutes.
If you need to shut off the pneumatic system for longer in order to carry out preven-
tive maintenance or servicing work, you must switch the machine off at the main
switch and disconnect it from the power supply.