00197902-03_UM_X-Serie-S_EN.pdf - 第216页

4 Setting up and commissioning User manual SIPLACE X-Series 4.2 Infrastructure at the installation location From software versio n 710.0 Edition 12/2016 216 4.2.3 Main power supply 4 Fig. 4.2 - 3 Position of power supply…

100%1 / 416
User manual SIPLACE X-Series 4 Setting up and commissioning
From software version 710.0 Edition 12/2016 4.2 Infrastructure at the installation location
215
4.2.2.2 Compressed air connection on the machine
4
Fig. 4.2 - 2 Compressed air unit on the machine
Legend for fig.4.2 - 2
(1) Manometer for the machine component supply pressure
Target pressure: 0.5 ± 0.025 MPa, 5 ± 0.25 bar (display range 0 - 1.0 MPa, 0 - 10 bar)
(2) Manometer for supply pressure of gantries 1 to 4
Target pressure: 0.46 ± 0.01 MPa, 4.6 ± 0.1 bar (display range 0 - 1.0 MPa, 0 - 10 bar)
(3) Manometer for inlet pressure
Target pressure: 0.5 - 1.0 MPa, 5 - 10 bar (display range: 0 - 1.0 MPa, 0 - 10 bar)
(4) Stop valve in the "OPEN" position
(5) Compressed air filter
(6) Compressed air connection
(6)
(1)
(2)
(3)
(5)
(4)
4 Setting up and commissioning User manual SIPLACE X-Series
4.2 Infrastructure at the installation location From software version 710.0 Edition 12/2016
216
4.2.3 Main power supply
4
Fig. 4.2 - 3 Position of power supply on the machine (example of SIPLACE X2 S / X3 S / X4 S shown)
(1) Lock
(2) Main power switch secured to prevent switching on again
(3) Power supply unit (behind the cover)
(4) Mains connection cable
(1)
(2)
(3)
(4)
User manual SIPLACE X-Series 4 Setting up and commissioning
From software version 710.0 Edition 12/2016 4.2 Infrastructure at the installation location
217
4.2.3.1 Danger notes
4
4
4.2.3.2 Checking the main power supply
Check whether the power supply complies with the prescribed machine specifications (see table
in section 3.2.3
, page 121).
4
DANGER
Dangerous voltage levels!
The machine is supplied with 3 x 360 V~ to 3 x 480 V ± 10 %, 50/60 Hz or optionally with
3 x 200 V~ to 3 x 240 V~ ± 10 %; 50/60 Hz mains voltage. This means that some parts of
the system carry potentially lethal voltages - even when switched off at the main power
switch and with disconnected mains plug.
Incorrect handling of this machine can therefore result in death or severe injury or consid-
erable damage to equipment.
Always follow the applicable accident prevention and DIN regulations (particularly EN
60204, part 1 or IEC 60204, part 1) and the applicable regulations in your own coun-
try.
The covers over the power supply unit may ONLY be opened by appropriately quali-
fied and trained personnel.
DANGER
Lethal voltages under the safety cutoff (CSB) cover!
Under the cover there are components which could still carry lethal voltages, even when
the machine is switched off and the mains plug has been disconnected. After disconnect-
ing the mains plug, wait 5 minutes until the capacitors have discharged.
Never open the covers.
Only ASM Assembly Systems GmbH&Co.KG service engineers or the machine
owner's service engineers, who have been trained by ASM, may perform work on the
power supply and the safety cutoff (CBS).
PLEASE NOTE
Load peaks in power supply
For technical reasons, load peaks occur in the power supply.
Please contact your power company to clarify the mains impedance, if necessary.