00197902-03_UM_X-Serie-S_EN.pdf - 第121页

User manual SIPLACE X-Series 3 Technical data and assemblies From software version 710.0 Edition 12/2016 3.2 Ambient conditions and connection values 121 3.2.3 Electrical ratings and energy consumption 3 3 PLEASE NOTE Us…

100%1 / 416
3 Technical data and assemblies User manual SIPLACE X-Series
3.2 Ambient conditions and connection values From software version 710.0 Edition 12/2016
120
3.2 Ambient conditions and connection values
3.2.1 Ambient conditions for packaging, transportation and storage
3
3.2.2 Ambient conditions for machine operation
3
Temperature range Between -25°C and 55°C
Atmospheric humidity Up to 95%
Ambient pressure Up to 3000 m height without pressure equalization
Room temperature Between 15°C and 35°C
Atmospheric humidity 30% to 75%
(on average not higher than 45%, so that there is no risk of
condensation on the machine.)
Ambient pressure > 750 mbar (corresponds to 2500 m above mean sea level)
User manual SIPLACE X-Series 3 Technical data and assemblies
From software version 710.0 Edition 12/2016 3.2 Ambient conditions and connection values
121
3.2.3 Electrical ratings and energy consumption
3
3
PLEASE NOTE
Use of a residual current protection device
The low ground leakage current of the system makes it possible to use an upstream
residual current protection device at the customer end. This must be all-current sen-
sitive (RCD type B).
SIPLACE X2 S
Electrical ratings
Supply voltage Fuse
Main power supply 3 x 360 V~ to 3 x 480 V~ ± 10 %; 50/60 Hz
3 x 200 V~ to 3 x 240 V~ ± 10 %; 50/60 Hz
*a
3 x 16A characteristic C
3 x 16A characteristic C
*b
Mains power con-
nection
Cable 5 x 4 mm² with CEKON connector (3 x 360 V~ to 3 x 480 V~)
Cable 5 x 4 mm² (3 x 200 V~ to 3 x 240 V)
Energy consumption
With a vacuum pump
*c
With two vacuum pumps
b
Without vacuum pumps
*d
Nominal apparent
power
2.7 kVA -- 1.4 kVA
Nominal active
power
1.8 kW -- 1.1 kW
SIPLACE X3 S
Electrical ratings
Supply voltage Fuse
Main power supply 3 x 360 V~ to 3 x 480 V~ ± 10 %; 50/60 Hz
3 x 200 V~ to 3 x 240 V~ ± 10 %; 50/60 Hz
a
3 x 16A characteristic C
3 x 16 A characteristic C
*b
Mains power con-
nection
Cable 5 x 4 mm² with CEKON connector (3 x 360 V~ to 3 x 480 V~)
Cable 5 x 4 mm² (3 x 200 V~ to 3 x 240 V)
Energy consumption
With one vacuum pump
b
With two vacuum pumps
b
Without vacuum pumps
c
Nominal apparent
power
2.7 kVA 4.1 kVA 1.4 kVA
Nominal active
power
1.8 kW 2.6 kW 1.1 kW
*)a With options package
*)b e.g. Siemens circuit breakers in accordance with IEC and UL 489 (order no.: 5SJ4 316-7HG42)
or
EATON Industries circuit breaker FAZ-C16/3-NA 16A 3p (UL 489, CSA C22.2 no. 5, IEC 60947-2)
*)c Vacuum pump for C&P20 head only.
*)d Optional
3 Technical data and assemblies User manual SIPLACE X-Series
3.2 Ambient conditions and connection values From software version 710.0 Edition 12/2016
122
3
SIPLACE X4 S / X4 S micron
Electrical ratings
Supply voltage Fuse
Main power supply 3 x 360 V~ to 3 x 480 V~ ± 10 %; 50/60 Hz
3 x 200 V~ to 3 x 240 V~ ± 10 %; 50/60 Hz
*a
3 x 16A characteristic C
3 x 16A characteristic C
*b
Mains power con-
nection
Cable 5 x 4 mm² with CEKON connector (3 x 360 V~ to 3 x 480 V~)
Cable 5 x 4 mm² (3 x 200 V~ to 3 x 240 V)
Energy consumption
With a vacuum pump
*c
With two vacuum pumps
b
Without vacuum pumps
*d
Nominal apparent
power
2.7 kVA 4.1 kVA 1.4 kVA
Nominal active
power
1.8 kW 2.6 kW 1.1 kW
SIPLACE X4i S / X4i S micron
Electrical ratings
Supply voltage Fuse
Main power supply 3 x 360 V~ to 3 x 480 V~ ± 10 %; 50/60 Hz
3 x 200 V~ to 3 x 240 V~ ± 10 %; 50/60 Hz
a
3 x 16A characteristic C
3 x 16 A characteristic C
*b
Mains power con-
nection
Cable 5 x 4 mm² with CEKON connector (3 x 360 V~ to 3 x 480 V~)
Cable 5 x 4 mm² (3 x 200 V~ to 3 x 240 V)
Energy consumption
With one vacuum pump
b
With two vacuum pumps
b
Without vacuum pumps
c
Nominal apparent
power
2.7 kVA 4.1 kVA 1.4 kVA
Nominal active
power
1.8 kW 2.6 kW 1.1 kW
*)a With options package
*)b e.g. Siemens circuit breakers in accordance with IEC and UL 489 (order no.: 5SJ4 316-7HG42)
or
EATON Industries circuit breaker FAZ-C16/3-NA 16A 3p (UL 489, CSA C22.2 no. 5, IEC 60947-2)
*)c Vacuum pump for C&P20 head only.
*)d Optional