00197902-03_UM_X-Serie-S_EN.pdf - 第126页

3 Technical data and assemblies User manual SIPLACE X-Series 3.3 Dimensions and weight From so ftware version 710.0 Edition 12/2016 126 3.3.1.2 Height of the folded up protective cover 3 Fig. 3.3 - 2 Height of the folded…

100%1 / 416
User manual SIPLACE X-Series 3 Technical data and assemblies
From software version 710.0 Edition 12/2016 3.3 Dimensions and weight
125
3.3.1.1 Overview of dimensions
3
Fig. 3.3 - 1 Overview of dimensions - example X2 S / X3 S / X4 S
Example:
(1) Length = 1948 mm
(2) Width = 2647 mm
(3) Height = 1852 mm
3 Technical data and assemblies User manual SIPLACE X-Series
3.3 Dimensions and weight From software version 710.0 Edition 12/2016
126
3.3.1.2 Height of the folded up protective cover
3
Fig. 3.3 - 2 Height of the folded-up protective cover - dimensions in millimeters (example of SIPLACE X4i S shown)
The specified dimensions refer to the max. PCB conveyor height of 950 mm.
(1) The height varies according to the set PCB conveyor height
for PCB conveyor height 900 mm = 195 mm ± 15 mm
for PCB conveyor height 930 mm = 225 mm ± 15 mm
for PCB conveyor height 950 mm = 245 mm ± 15 mm
User manual SIPLACE X-Series 3 Technical data and assemblies
From software version 710.0 Edition 12/2016 3.3 Dimensions and weight
127
3.3.2 For a definition of placement performance values
3
Fig. 3.3 - 3 Maneuvering distances of component trolleys in X-Series machines
The maneuvering distances R for the component trolley of the SIPLACE X-Series machines are
as follows:
3
3
3
Maneuvering distance R location position 600 mm
Distance L1: Machine center to outer edge of X component
trolley
1470 mm
Distance L2: Machine center to wall 2070 mm