00197902-03_UM_X-Serie-S_EN.pdf - 第373页
User manual SIPLACE X-Series 6 Station extensions From software version 710.0 Ed ition 12/2016 6.8 Docking station for the component trolley of the SIPLACE X-Series 373 6.8.4 Controls and displays 6 Fig. 6.8 - 4 Docking …

6 Station extensions User manual SIPLACE X-Series
6.8 Docking station for the component trolley of the SIPLACE X-Series From software version 710.0 Edition 12/2016
372
6
6
6.8.3 Dimensions of docking station with docked component trolley
6
Fig. 6.8 - 3 Docking station with docked component trolley - dimensions in millimeters
(1) Component trolley
(2) Docking station
Compressed air connection Connection plug KS 2-M5-A
Compressed air consumption 50 Nl/min
*a
Supply voltage 88 - 264 V~
Rated current 3.5 A (230 V~)
7 A (115 V~)
Performance 0.8 kW
*)a Under normal atmospheric conditions at 20°C and 1013 hPa

User manual SIPLACE X-Series 6 Station extensions
From software version 710.0 Edition 12/2016 6.8 Docking station for the component trolley of the SIPLACE X-Series
373
6.8.4 Controls and displays
6
Fig. 6.8 - 4 Docking station - controls and displays

6 Station extensions User manual SIPLACE X-Series
6.8 Docking station for the component trolley of the SIPLACE X-Series From software version 710.0 Edition 12/2016
374
Legend for fig. 6.8 - 4
, page 373.
(1) Button with control lamp for mains power supply
(2) Button for locking and unlocking all feeder modules on the component trolley
(3) Clamping lever for fastening the changeover table - lever in position "closed"
(4) Label with diagram of switch S1 and S2 for addressing the CAN bus
(5) Switch S1 and S2 for setting the CAN bus address
(6) Mains switch
(7) Rotary knob for setting the operating pressure
(8) Manometer for showing the operating pressure