00197902-03_UM_X-Serie-S_EN.pdf - 第276页
5 Working with the machine User manual SIPLACE X-Series 5.7 Indicator lamps with horn From softwa re version 710.0 Edition 12/2016 276 5.7.1.2 Three color indicator lamp (optional) Fig. 5.7 - 2 Indicator lamps for operat…

User manual SIPLACE X-Series 5 Working with the machine
From software version 710.0 Edition 12/2016 5.7 Indicator lamps with horn
275
5.7 Indicator lamps with horn
5.7.1 Overview
These indicator lamps are used to signal operating statuses and malfunctions of the machine. The
horn indicates when an alert has occurred. SIPLACE machines can either be fitted with a two or
three color indicator lamp. The relevant indicator lamp system (two or three color) is set in the au-
toconfiguration, see installation guide for station software, Item No. 00196771-xx.
5.7.1.1 Two color indicator lamp (standard)
Fig. 5.7 - 1 Indicator lamps for operating states (example of SIPLACE X2 S / X3 S / X4 S shown)
L1 White indicator lamp, right
L2 Green indicator lamp, right
L3 White indicator lamp, left
L4 Green indicator lamp, left
T Direction of PCB transport
(L2)
(L1)
(L3)
(L4)

5 Working with the machine User manual SIPLACE X-Series
5.7 Indicator lamps with horn From software version 710.0 Edition 12/2016
276
5.7.1.2 Three color indicator lamp (optional)
Fig. 5.7 - 2 Indicator lamps for operating states (example of SIPLACE X2 S / X3 S / X4 S shown)
L1 red indicator lamp
L2 yellow indicator lamp
L3 green indicator lamp
(L2)
(L1)
(L3)

User manual SIPLACE X-Series 5 Working with the machine
From software version 710.0 Edition 12/2016 5.7 Indicator lamps with horn
277
5.7.2 Status displays and their meanings
5
Meaning Machine side Status - two color
(white/green)
Status - three color
(red/yellow/green)
The automatic mode is enabled
but the machine is not yet pro-
ducing.
Both sides White: Off
Green: 700-700
Horn: Off
Red: Off
Yellow: Off
Green: Flashes
Horn: Off
The machine is producing. Both sides White: Off
Green: On
Horn: Off
Red: Off
Yellow: Off
Green: On
Horn: Off
The machine is waiting for a
board at input.
Both sides Not configured Red: Off
Yellow: Off
Green: 500 - 500
Horn: Off
The machine is performing a
reference run.
Both sides Not configured Red: Off
Yellow: Off
Green: Flashes
Horn: Off
The machine has been stopped
with the stop button; The start
button must be pressed to con-
tinue production.
Both sides Not configured Red: Off
Yellow: Off
Green: Flashes
Horn: Off
Unable to read the board bar-
code in the input conveyor. The
operator must insert the board
manually.
Respective side Not configured Red: Off
Yellow: Flashes
Green: Off
Horn: Off
The machine is preparing pro-
duction (check nozzle status,
feeder modulerecognition).
Both sides White: Off
Green: On
Horn: Off
Red: Off
Yellow: Off
Green: On
Horn: Off
Fiducial manipulation by the
operator required.
Both sides White: Off
Green: 100 - 100
Horn: Off
Red: Off
Yellow: On
Green: Off
The machine is waiting for a
recipe or is waiting for machine
preparation after receiving a
recipe.
Both sides White: Off
Green: 100 - 100
Horn: Off
Red: Off
Yellow: Off
Green: Flashes
Horn: Off
An alternative pickup position
will be used.
Respective side White: 100 -100
Green: Off
Horn: Off
Red: Off
Yellow: On
Green: On
Horn: Off