00197902-03_UM_X-Serie-S_EN.pdf - 第123页
User manual SIPLACE X-Series 3 Technical data and assemblies From software version 710.0 Edition 12/2016 3.2 Ambient conditions and connection values 123 3.2.4 Compressed air supply and compressed air specification 3 Com…

3 Technical data and assemblies User manual SIPLACE X-Series
3.2 Ambient conditions and connection values From software version 710.0 Edition 12/2016
122
3
SIPLACE X4 S / X4 S micron
Electrical ratings
Supply voltage Fuse
Main power supply 3 x 360 V~ to 3 x 480 V~ ± 10 %; 50/60 Hz
3 x 200 V~ to 3 x 240 V~ ± 10 %; 50/60 Hz
*a
3 x 16A characteristic C
3 x 16A characteristic C
*b
Mains power con-
nection
Cable 5 x 4 mm² with CEKON connector (3 x 360 V~ to 3 x 480 V~)
Cable 5 x 4 mm² (3 x 200 V~ to 3 x 240 V)
Energy consumption
With a vacuum pump
*c
With two vacuum pumps
b
Without vacuum pumps
*d
Nominal apparent
power
2.7 kVA 4.1 kVA 1.4 kVA
Nominal active
power
1.8 kW 2.6 kW 1.1 kW
SIPLACE X4i S / X4i S micron
Electrical ratings
Supply voltage Fuse
Main power supply 3 x 360 V~ to 3 x 480 V~ ± 10 %; 50/60 Hz
3 x 200 V~ to 3 x 240 V~ ± 10 %; 50/60 Hz
a
3 x 16A characteristic C
3 x 16 A characteristic C
*b
Mains power con-
nection
Cable 5 x 4 mm² with CEKON connector (3 x 360 V~ to 3 x 480 V~)
Cable 5 x 4 mm² (3 x 200 V~ to 3 x 240 V)
Energy consumption
With one vacuum pump
b
With two vacuum pumps
b
Without vacuum pumps
c
Nominal apparent
power
2.7 kVA 4.1 kVA 1.4 kVA
Nominal active
power
1.8 kW 2.6 kW 1.1 kW
*)a With options package
*)b e.g. Siemens circuit breakers in accordance with IEC and UL 489 (order no.: 5SJ4 316-7HG42)
or
EATON Industries circuit breaker FAZ-C16/3-NA 16A 3p (UL 489, CSA C22.2 no. 5, IEC 60947-2)
*)c Vacuum pump for C&P20 head only.
*)d Optional

User manual SIPLACE X-Series 3 Technical data and assemblies
From software version 710.0 Edition 12/2016 3.2 Ambient conditions and connection values
123
3.2.4 Compressed air supply and compressed air specification
3
Compressed air supply
Compressed air pressure val-
ues
p
min
p
max
0.5 MPa = 5.0 bar
1.0 MPa = 10 bar
Operating pressure 0.48 MPa ± 0.025 MPa (4.8 bar ± 0.25 bar)
Compressed air connection R 3/4" inner thread (pipe thread) with 1/2" hose connection
Compressed air consumption
*a
Placement head configuration Compressed air
consumption
*b
with vacuum pump
Compressed air con-
sumption
without vacuum
pump
*c
SIPLACE X4i S / X4 S
C&P20/C&P20/C&P20/C&P20
C&P20/C&P20/CPP/CPP
C&P20/C&P20/TH/TH
C&P20/C&P20/CPP_H
*d
/TH
CPP/CPP/CPP/CPP
CPP/CPP/CPP_H/TH
CPP/CPP/TH/TH
CPP/TH/TH/TH
TH/TH/TH/TH
260 Nl/min
370 Nl/min
330 Nl/min
350 Nl/min
480 Nl/min
460 Nl/min
440 Nl/min
420 Nl/min
400 Nl/min
990 Nl/min
720 Nl/min
680 Nl/min
700 Nl/min
480 Nl/min
460 Nl/min
440 Nl/min
420 Nl/min
400 Nl/min
SIPLACE X4 S micron
C&P20 M/C&P20 M/C&P20 M/C&P20 M
C&P20 M/C&P20 M/CPP/CPP
260 Nl/min
370 Nl/min
990 Nl/min
720 Nl/mi
SIPLACE X4i S micron
C&P20 M/C&P20 M/C&P20 M/C&P20 M
C&P20 M/C&P20 M/CPP/CPP
260 Nl/min
370 Nl/min
990 Nl/min
720 Nl/min
SIPLACE X3 S
C&P20/C&P20/C&P20
C&P20/C&P20/CPP
C&P20/C&P20/TH
CPP/CPP/CPP
CPP / TH
CPP/TH/TH
TH/TH/TH
185 Nl/min
230 Nl/min
230 Nl/min
360 Nl/min
340 Nl/min
340 Nl/min
300 Nl/min
720 Nl/min
600 Nl/min
590 Nl/min
360 Nl/min
340 Nl/min
340 Nl/min
300 Nl/min
SIPLACE X2 S
C&P20 / C&P20
C&P20/CPP
C&P20/TH
CPP / CPP
CPP / TH
TH / TH
130 Nl/min
185 Nl/min
165 Nl/min
240 Nl/min
220 Nl/min
200 Nl/min
480 Nl/min
360 Nl/min
340 Nl/min
240 Nl/min
220 Nl/min
200 Nl/min
Compressed air specification
Particle size 0.1 µm
Particle density 0.1 mg/m³
Maximum oil content (class
1)
Particle density 0.01 mg/m³
Pressure dewpoint (class 4) Dewpoint + 3°
*)a Average consumption values.
*)b Under normal atmospheric conditions at 20°C and 1013 hPa.
*)c Optional
*)d CPP_H = Multistar CPP in high assembly position

3 Technical data and assemblies User manual SIPLACE X-Series
3.3 Dimensions and weight From software version 710.0 Edition 12/2016
124
3.3 Dimensions and weight
3.3.1 Technical data - dimensions and weight
3
Length
*a
Without conveyor extension and without hand guard
Without conveyor extension and with hand guard
With conveyor extension (one end)
With conveyor extension (two ends)
1915 mm
1948 mm
2191 mm
2433 mm
Width
Outer contour of machine protection
With monitor and keyboard
On the component trolley and table position "outermost" (handle folded in)
On the component trolley and table position "outermost" (handle folded out)
2647 mm
2940 mm
2890 mm
3640 mm
Height of machine (for PCB conveyor height 930 mm)
Up to upper edge of monitor
With 2-color indicator lamp
With 3-color indicator lamp
Without indicator lamp (height of packaging)
With folded-up protective covers
1630 mm
1852 mm
1893 mm
1658 mm
2120 mm
Machine ground clearance
(for PCB conveyor height 900 mm)
(for PCB conveyor height 930 mm)
(for PCB conveyor height 950 mm)
195 mm ± 15 mm
225 mm ± 15 mm
245 mm ± 15 mm
Weight
SIPLACE X4i S / X4i S micron (machine without component trolley)
SIPLACE X4i S / X4i S micron (fully equipped with feeder modules)
SIPLACE X4 S / X4 S micron (machine without component trolley)
SIPLACE X4 S / X4 S micron (fully equipped with feeder modules)
SIPLACE X3 S (machine without component trolley)
SIPLACE X3 S (fully equipped with feeder modules)
SIPLACE X2 S (machine without component trolley)
SIPLACE X2 S (fully equipped with feeder modules)
3,430 kg
4,000 kg
3,430 kg
4,000 kg
3,410 kg
3,970 kg
3,390 kg
3,950 kg
Location
*b
5.73 m²
Load per unit area
X-Series with 4 component trolley X 6.1 kN/m²
Number of machine feet 6
Max. noise emissions 75 dB (A)
Room temperature Between 15°C and 35°C
Atmospheric humidity 30% to 75
% (no higher than 45% on average to
prevent any possibility of condensa-
tion on the machine)
*)a Measured at the outer contour of the machine protection.
*)b Measured at the outer contour of the machine protection and at the keyboard (without conveyor extension).
Please note
The compressed air consumption values are identical for the C&P20, C&P 20 M and C&P20 P.