00197902-03_UM_X-Serie-S_EN.pdf - 第278页

5 Working with the machine User manual SIPLACE X-Series 5.7 Indicator lamps with horn From softwa re version 710.0 Edition 12/2016 278 A board ne eds to be tak en out of the output conveyor (e.g. for inspection). Respect…

100%1 / 416
User manual SIPLACE X-Series 5 Working with the machine
From software version 710.0 Edition 12/2016 5.7 Indicator lamps with horn
277
5.7.2 Status displays and their meanings
5
Meaning Machine side Status - two color
(white/green)
Status - three color
(red/yellow/green)
The automatic mode is enabled
but the machine is not yet pro-
ducing.
Both sides White: Off
Green: 700-700
Horn: Off
Red: Off
Yellow: Off
Green: Flashes
Horn: Off
The machine is producing. Both sides White: Off
Green: On
Horn: Off
Red: Off
Yellow: Off
Green: On
Horn: Off
The machine is waiting for a
board at input.
Both sides Not configured Red: Off
Yellow: Off
Green: 500 - 500
Horn: Off
The machine is performing a
reference run.
Both sides Not configured Red: Off
Yellow: Off
Green: Flashes
Horn: Off
The machine has been stopped
with the stop button; The start
button must be pressed to con-
tinue production.
Both sides Not configured Red: Off
Yellow: Off
Green: Flashes
Horn: Off
Unable to read the board bar-
code in the input conveyor. The
operator must insert the board
manually.
Respective side Not configured Red: Off
Yellow: Flashes
Green: Off
Horn: Off
The machine is preparing pro-
duction (check nozzle status,
feeder modulerecognition).
Both sides White: Off
Green: On
Horn: Off
Red: Off
Yellow: Off
Green: On
Horn: Off
Fiducial manipulation by the
operator required.
Both sides White: Off
Green: 100 - 100
Horn: Off
Red: Off
Yellow: On
Green: Off
The machine is waiting for a
recipe or is waiting for machine
preparation after receiving a
recipe.
Both sides White: Off
Green: 100 - 100
Horn: Off
Red: Off
Yellow: Off
Green: Flashes
Horn: Off
An alternative pickup position
will be used.
Respective side White: 100 -100
Green: Off
Horn: Off
Red: Off
Yellow: On
Green: On
Horn: Off
5 Working with the machine User manual SIPLACE X-Series
5.7 Indicator lamps with horn From software version 710.0 Edition 12/2016
278
A board needs to be taken out
of the output conveyor (e.g. for
inspection).
Respective side White: 500 -500
Green: 700 -700
Horn: On
Red: Off
Yellow: Off
Green: Flashes
Horn: On
The PCB conveyor is jammed
(successor machine is waiting
for boards).
Respective side Not configured Red: Off
Yellow: Off
Green: Flashes
Horn: Off
More than one pickup position
with the same components is
disabled but there is more than
one pickup position available
for use.
Respective side White: 500 -500
Green: Off
Horn: Off
Red: Off
Yellow: On
Green: On
Horn: Off
Setup verification is required
for at least one pickup position.
Respective side White: 500 -500
Green: Off
Horn: Off
Red: Off
Yellow: Flashes
Green: Off
Horn: Off
The nozzle setup is not com-
plete.
Respective side White: 500 -500
Green: Off
Horn: Off
Red: Off
Yellow: On
Green: On
Horn: Off
The last available pickup posi-
tion is being used or there is no
pickup position left for this com-
ponent. The machine will con-
tinue to produce while there are
still other components which
can be placed.
Respective side White: 100 -200
Green: Off
Horn: Off
Red: Off
Yellow: On
Green: On
Horn: Off
The filling level of the pickup
position or dipping module is
low.
Respective side White: 100 -200
Green: Off
Horn: Off
Red: Off
Yellow: On
Green: On
Horn: Off
The machine has been auto-
matically stopped due to a non-
configured event e.g. conveyor
error. Events which have not
been configured and which
could lead to a machine stop
have not be taken into consid-
eration here.
Respective side White: On
Green: Off
Horn: Off
Red: Off
Yellow: Flashes
Green: Off
Horn: Off
The production has been auto-
matically stopped (e.g. there is
no component ready for pick-
up).
Respective side White: On
Green: Off
Horn: Off
Red: Off
Yellow: Flashes
Green: Off
Horn: Off
Meaning Machine side Status - two color
(white/green)
Status - three color
(red/yellow/green)
User manual SIPLACE X-Series 5 Working with the machine
From software version 710.0 Edition 12/2016 5.7 Indicator lamps with horn
279
5.7.2.1 Basics
5
5.7.2.2 Frequency of flashes
5
5
The machine is performing a
manual function triggered by
the operator.
Both sides White: 100 -1000
Green: 700 - 700
Horn: Off
Red: Off
Yellow: Off
Green: Flashes
Horn: Off
Unable to move one of the
boards to the next area.
Respective side Not configured Red: Off
Yellow: Flashes
Green: Off
Horn: Off
The machine has been stopped
due to a fiducial measurement
error ( z. B. board, table, feeder
module).
Both sides White: On
Green: Off
Horn: Off
Red: Off
Yellow: Flashes
Green: Off
Horn: Off
The safety loop has not closed. Respective side White: On
Green: Off
Horn: Off
Red: On
Yellow: Off
Green: Off
Horn: Off
The machine reports a ma-
chine error.
Respective side
or both sides
White: On
Green: Off
Horn: On
Red: On
Yellow: Off
Green: Off
Horn: On
Meaning Machine side Status - two color
(white/green)
Status - three color
(red/yellow/green)
Status Meaning
Off No warning and no alert
Flashes Warning, the frequency varies depending on the type of warning
On Alert
Normal flashing Green indicator lamp: 700 ms off, 700 ms on
White indicator lamp: 500 ms off, 500 ms on
Short flashing 100 ms off, 1000 ms on
Fast flashing 100 ms off, 200 ms on