00197902-03_UM_X-Serie-S_EN.pdf - 第361页
User manual SIPLACE X-Series 6 Station extensions From software version 710.0 Edition 12/201 6 6.5 Waffle pack changer (WPC5/WPC6) 361 6.5.6 Maneuvering radii for WPC5/WPC6 6 Fig. 6.5 - 2 Maneuvering radius for WPC5/WPC6…

6 Station extensions User manual SIPLACE X-Series
6.5 Waffle pack changer (WPC5/WPC6) From software version 710.0 Edition 12/2016
360
6.5.5.2 Electrical ratings
6
6.5.5.3 Permitted environmental factors
6
Supply voltage 3 x 200 V~ ± 5 %; 50/60 Hz (Japan)
3 x 208 V~ ± 5 %; 50/60 Hz (U.S.A)
3 x 230 V~ ± 5 %; 50/60 Hz
3 x 380 V~ ± 5 %; 50/60 Hz
3 x 400 V~ ± 5 %; 50/60 Hz (Europe)
3 x 415 V~ ± 5 %; 50/60 Hz
Nominal apparent power
1.5 kVA
Nominal active power
1.0 kW
Room temperature Between 15°C and 35°C
Atmospheric humidity 30 - 75%
(on average not higher than 45%, so that there is no risk of
condensation on the machine.)

User manual SIPLACE X-Series 6 Station extensions
From software version 710.0 Edition 12/2016 6.5 Waffle pack changer (WPC5/WPC6)
361
6.5.6 Maneuvering radii for WPC5/WPC6
6
Fig. 6.5 - 2 Maneuvering radius for WPC5/WPC6 at the SIPLACE X-Series S
The maneuvering radius R for the WPC5/WPC6 is:
6
6.5.7 Installation notes for WPC5/WPC6
The WPC5/WPC6 can be docked onto location 2.
Maneuvering radius R 750 mm
Distance L1: Machine center to outer edge of WPC (handles) 2100 mm
Distance L2: Machine center to wall 2850 mm

6 Station extensions User manual SIPLACE X-Series
6.5 Waffle pack changer (WPC5/WPC6) From software version 710.0 Edition 12/2016
362
6.5.8 Dimensions with WPC5/WPC6
6
Fig. 6.5 - 3 Dimensions for WPC5/WPC6 at the SIPLACE X-Series S