00197902-03_UM_X-Serie-S_EN.pdf - 第60页
2 Operational safety User manual SIPLACE X-Series 2.2 Warning labels From software version 710.0 Edition 12/2016 60 2.2.3 W arning labels on the gantries Fig. 2.2 - 4 Warning label W202 on the gantries (example of SIPLAC…

User manual SIPLACE X-Series 2 Operational safety
From software version 710.0 Edition 12/2016 2.2 Warning labels
59
2.2.2.1 Warning label W203
2
W203 in fig. 2.2 - 3, page 58 item no. 03009342-01 (quantity per machine: 4)
2.2.2.2 Safety instructions for work performed with the protective cover open
2
A black-yellow warning strip is attached to the input and output conveyors. Item 1 in the fig. 2.2 -
3, page 58 (Quantity per machine: 2)
This warns the operator not to reach into the inside of the neighboring machine.
2
2
2
2
DANGER OF CRUSHING!
Reaching in here can lead to injuries to the arms and hands.
Do not reach into the inside of the neighboring machine.
DANGER
Risk of injury when protective cover open!
There is a risk of injuries if you reach into the hazard area of the adjacent machine when
the protective cover is open. This area is marked with black-and-yellow warning strips.
Take care not to reach into the hazard area of the adjacent machine when the pro-
tective cover is open.
2
2
2
RISK OF HAND INJURIES (CRUSHING) IN EXTENSIVE AREA!
Reaching in here can lead to injuries to the arms and hands.
Do not reach into the inside of the neighboring machine.

2 Operational safety User manual SIPLACE X-Series
2.2 Warning labels From software version 710.0 Edition 12/2016
60
2.2.3 Warning labels on the gantries
Fig. 2.2 - 4 Warning label W202 on the gantries (example of SIPLACE X4i S shown)
2
W202, item no. 03009341-01
W 202
W 202
W 202
W 202

User manual SIPLACE X-Series 2 Operational safety
From software version 710.0 Edition 12/2016 2.2 Warning labels
61
2.2.3.1 Warning label 202
2
W202, in fig. 2.2 - 4, page 60, item no. 03009341-01
(quantity per machine: 4)
2
2
2
CAUTION
Data loss due to powerful magnetic fields!
There is a risk that the powerful magnetic fields could corrupt data on data media or credit
cards and check cards.
Keep data carriers and check cards away from the machine.
DANGER
Danger to life from powerful magnetic fields inside the machine!
When protective covers are opened inside the machine, the life of persons with the fol-
lowing passive or active implants is put at risk:
– Pacemakers
– Defibrillators
– Insulin pumps etc.
At-risk people must not stand in the immediate vicinity of the machine.
WARNING
DANGER OF CRUSHING!
There is a danger of crushing for persons with passive metal implants (e.g. plates,
screws).
Never reach into the machine when the protective covers are open and do not bend
over the open machine.
Do not bring any metal objects into the danger area.