80S-15贴片机.pdf - 第390页

9 Revolver Head SIPLACE 80S/F/G Service Manual Edition 04/97 9 - 106

100%1 / 484
SIPLACE 80S/F/G Service Manual 9 Revolver Head
Edition 04/97
9 - 105
9.13.4 Adjustments
Carry out the adjustments in accordance with the adjustment instructions.
Calibrate the placement head using the SITEST program.
Fig. 9.13.1 Fitting the encoder housing to the lifting carriage housing
Key to Fig. 9.13.1
1 Cover 4 Lifting carriage housing
2 M4 fixing screws 5 Parallel pins
3 Encoder housing
1
3
4
5
5
2
9 Revolver Head SIPLACE 80S/F/G Service Manual
Edition 04/97
9 - 106
SIPLACE 80S/F/G Service Manual 9 Revolver Head
Edition 04/97
9 - 107
9.14 Dismantling the housing cover
9.14.1 Tools, equipment and consumables
9.14.2 Dismantling the PCB camera
DANGER
OOO
Switch the placement machine off at the main switch and disconnect from the power supply.
Remove connector X1 of cable Y0577 (point 5 in Fig. 9.14.1) from terminal X1 on board Y0029.
Remove connector X3 (point 6 in Fig. 9.14.1) of the lens system lighting cable from terminal X2 on board
Y0029.
Remove connector X1 of the PCB camera cable Y0597 (see item 2 in Fig. 9.14.1) from the PCB camera
amplifier.
Loosen the cable clip (see item 3 in Fig. 9.14.1).
Dismantle the red retaining bracket.
Loosen the 4 M3 hexagon socket-head screws (see item 6 in Fig. 9.14.2) for fixing the PCB camera holder
(see item 5 in Fig. 9.14.2).
From item number
Set of hexagon socket-head screwdrivers
Diagonal cutter
Cable ties
SITEST program