3
Basic adjustments
3-28
1. Camera parameter adjustments
1.2.4 Calibrating the single-vision camera scale
When calibrating the single-vision camera scale, the same glass QFP as for multi-vision
camera adjustment is used. Have the glass QFP ready before beginning calibration.
c
CAUTION
Single-vision cameras are optional. The number of single-vision cameras installed in one
machine depends on the machine's specifications. (No single-vision cameras are installed in
standard specification machines.) Check your machine's specifications.
In the single-vision camera adjustment dialog box, the single-vision camera number is shown
as "Analog single 1" or "Analog single 2" when the second single-vision camera is installed.
1
Check the "Adjust Mode" parameter and PCB data.
Calibration of the single-vision camera scale uses a glass QFP, so the machine must be
set to "Adjust Mode2" and the "MCH_SETUP" PCB data loaded into the machine.
You can check the currently selected PCB data and "Adjust Mode" on the status bar.
Status bar display
Status bar shows currently selected PCB data and "Adjust Mode".
27085-X9-00
n
NOTE
To calibrate the single-vision camera scale, the machine must be set to "Adjust Mode2" (see sections 2.5 and 2.6
in Chapter 2) and the "MCH_SETUP" PCB data loaded into the machine (see section 2.7 in Chapter 2).

3
Basic adjustments
3-29
1. Camera parameter adjustments
2
Press the [Utilities] button to start the adjustment utility.
n
NOTE
For how to start the adjustment utility, see section 2.4 in Chapter 2.
3
Press the [Single Camera] button in the adjustment utility menu
window.
The single-vision camera adjustment dialog box appears.
Adjustment utility menu window
[Single Camera] button
27021-X9-D0
4
Select the "Scale" option button under "Adjust Item".
n
NOTE
Also check that other items in the single-vision camera adjustment dialog box are set as follows.
Camera : Analog Single 1 or 2
Comp. No. : 11 (glass QFP)
Distance : 3.00
Single-vision camera adjustment dialog box
Select the "Scale" option button.
27094-X9-00
n
NOTE
Only numbers up to 10 are selectable from the drop-down list of the "Comp. No." combo box, so enter "11" from
the keyboard. In the "MCH_SETUP" PCB data, component No.11 is assigned to glass QFP (KMO-M880A-202).

3
Basic adjustments
3-30
1. Camera parameter adjustments
Component No. combo box
Enter "11".
27095-X9-00
27096-X9-00
5
Press the [Pickup] button in the single-vision camera adjustment
dialog box.
The head assembly moves to the component pickup position and the confirmation
dialog box appears.
Confirmation dialog box
27097-X9-00
6
Press the emergency stop button and attach the glass QFP to Head 1.
Attach the glass QFP to the nozzle of Head 1, with the pin-pattern-printed surface
facing down (toward the camera), and then press the [OK] button.
n
NOTE
Handle the glass QFP carefully and protect it from dust and grime. Dust, grime or nicks on the glass QFP surface
may cause recognition errors or result in poor adjustment.
Make sure the nozzle picks up the center of the glass QFP.
e