Dual Simultaneous Programmable Pitch Rev 02.pdf - 第11页

© 2024 Nordson Corporation 7 3 Inst allation and Configuration 3.1 Overview The DSPP should c ome already i nstalled and con figured for yo ur conformal c oating sys tem. The DSP P may need minor adjustmen ts from time t…

100%1 / 72
Dual-Simultaneous Programmable Pitch Owner’s Manual Safety
6 © 2024 Nordson Corporation
2.6 Emergency Shutdown
In the event of an emergency or malfunction, press the EMO (E-Stop) button on the conformal coating
system and perform the following steps:
Disconnect and lockout system electrical power. Close hydraulic and pneumatic shutoff
valves and relieve pressure.
Identify the reason for the malfunction and correct it before restarting the system.
2.7 Safety Warning Labels
Safety warning labels on your equipment point out areas where personnel must use extreme caution to
prevent serious injury and property damage. Refer to the applicable coating system Installation,
Operations, and Maintenance Manual for important safety information and conformal coating system label
locations.
WARNING!
Comply with all safety warning labels on the conformal coating system and
optional equipment or serious injury to personnel or damage to the conformal
coating system may occur. Replace worn or damaged labels.
© 2024 Nordson Corporation 7
3 Installation and Configuration
3.1 Overview
The DSPP should come already installed and configured for your conformal coating system. The DSPP
may need minor adjustments from time to time, or after changing applicators. This section includes the
following instructions:
Adjusting Limit Sensor
Adjusting Y
-
Adjusting Applicator Height
Third Valve Option
Adjusting Applicator Pitch
3.2 Safety First
Operation of the Dual-Simultaneous Programmable Pitch involves mechanical devices and electrical
power. It is essential that every person servicing or operating the DSPP fully understands all hazards,
risks, and safety precautions. See Section 2 - Safety for additional information.
WARNING!
Allow only qualified personnel to perform the following tasks. Follow the safety
instructions in this document and all other related documentation.
WARNING!
Ensure the fluid system is completely depressurized prior to loosening any fittings
in the fluid path. Failure to do so may cause serious injury to personnel.
3.3 Tools and Materials Needed
Torque Wrench
Metric Hex Key Set
3.4 Unpacking the DSPP
Every care has been taken when packaging the DSPP. However, we recommend that you look for
obvious damage and verify contents against the packing slip.
Retain the case for storage of the DSPP and accessories. Retain shipping cartons for future use. If an
item needs to be returned to Nordson, obtain a Return Material Authorization (RMA) number from
Nordson, see 7.3 Parts Ordering Information.
Dual-Simultaneous Programmable Pitch Owner’s Manual Installation and Configuration
8 © 2024 Nordson Corporation
3.5 Adjusting Limit Sensor
To adjust the limit sensor (Figure 3-1):
1. Loosen the two (2) screws on the front of the limit sensor.
?
NOTE
There are nuts on the back of each screw. Do not loosen the screws too much or
the nuts will off.
2. Slide the limit sensor to the appropriate position, depending on which applicator is
configured for the coating system, see Table 1-1.
3. Tighten the two (2) screws on the front of the limit sensor.
?
NOTE
The limit sensor may need to be adjusted after installing the applicator to prevent
applicators from colliding when traveling to the narrowest pitch.
Item Description
1 Limit Sensor
2 Screws (2)
Figure 3-1 Position Limit Sensor
1
2