Dual Simultaneous Programmable Pitch Rev 02.pdf - 第34页

Dual-Simultaneous Pr ogrammable Pitch Owner ’s Manual Operation 30 © 2024 Nordson Corporation 6. Scroll thro ugh the Cal & Verif y proce dure until you loca te the app licator names (Figure 4-14). C lick o n the firs…

100%1 / 72
Dual-Simultaneous Programmable Pitch Owner’s Manual Operation
© 2024 Nordson Corporation 29
17. Click Exit in the RunACL window.
18. Restart EasyCoat.
4.5.2 Perform Calibration Routine
The calibration routine should be performed at initial startup and any time the home flag, home sensor, or
applicators are removed or replaced.
To perform the calibration routine:
1. Open the EasyCoat software.
2. In the Operator Screen, select Edit > Edit Mode.
3. In the Edit Screen, select View > Macro Program.
4. In the Edit Screen, click on the Open icon, select Macro auto pitch_3.ECM from the
programs menu and click Open (Figure 4-12).
Figure 4-12 Open Macros
5. In the Edit Screen, locate and click on the procedure Cal & Verify (Figure 4-13).
Figure 4-13 Select Cal & Verify Procedure
Dual-Simultaneous Programmable Pitch Owner’s Manual Operation
30 © 2024 Nordson Corporation
6. Scroll through the Cal & Verify procedure until you locate the applicator names
(Figure 4-14). Click on the first applicator name to highlight it.
Figure 4-14 Locate Applicator Names
7. Click on the Value for Tool to activate the drop-down list (Figure 4-15).
?
NOTE
Make a note of the exact name of each applicator on the drop-down list.
Figure 4-15 Activate Drop-Down Menu
Dual-Simultaneous Programmable Pitch Owner’s Manual Operation
© 2024 Nordson Corporation 31
8. Change the applicator names in the Cal & Verify procedure by highlighting one of them
(e.g., Film Coater Left) and then selecting the corresponding applicator from the drop-down
list (Figure 4-16).
Figure 4-16 Select Applicator Name
9. Repeat Step 8 until all applicator entries have been changed (Figure 4-17).
Figure 4-17 All Applicator Names Changed