Dual Simultaneous Programmable Pitch Rev 02.pdf - 第17页

Dual-Simultaneous Pr ogrammable Pitch Owner ’s Manual In stallation and Configuratio n © 2024 Nordson Corporation 13 Item Description 1 Pitch Motor and Pitch ENC and Sensors Connections (DO NOT HOT SWAP) 2 Toggle V1 Top …

100%1 / 72
Dual-Simultaneous Programmable Pitch Owner’s Manual Installation and Configuration
12 © 2024 Nordson Corporation
3.9 Third Valve Option
?
NOTE
The third valve option installation requires Technical Support assistance to assist with
configuring the 3
rd
applicator for dual simultaneous programmable pitch and assistance
with setting up dual or triple toggle brackets. Contact Technical Support for additional
information.
The third valve option is available for the DSPP as an add-on toggle bracket assembly. Contact Technical
Support for ordering information.
WARNING!
When installing, performing maintenance, or making adjustments with power on,
do not hot swap the Pitch Motor and Pitch ENC and Sensors cables on the
Z-head (Figure 3-5).
3.9.1 Installing the Third Valve Option
To install the third valve option (Figure 3-5):
1. Perform a service shutdown. Refer to the SL-1040 Conformal Coating System Installation,
Operations, and Maintenance Manual for instructions.
2. Open the front hood of the conformal coating system.
3. Manually move the dispense head to the front of the conformal coating system.
4. Mount the toggle bracket assembly to the right side of the DSPP base plate using the
hardware included.
5. Connect the white tubing from Toggle V1 to the cylinder.
6. Connect the white tubing from Toggle V3 (top) to the right side of the DSPP.
7. Connect the black tubing from Toggle V3 (bottom) toggle to the bottom right side of the
DSPP.
Dual-Simultaneous Programmable Pitch Owner’s Manual Installation and Configuration
© 2024 Nordson Corporation 13
Item Description
1
Pitch Motor and Pitch ENC and Sensors
Connections (DO NOT HOT SWAP)
2 Toggle V1 Top Connection (White Tubing)
3 Toggle V3 Top Connection (White Tubing)
4 Toggle V3 Bottom Connection (Black Tubing)
Figure 3-5 Third Valve Option
4
3
3
3
4
2
1
Dual-Simultaneous Programmable Pitch Owner’s Manual Installation and Configuration
14 © 2024 Nordson Corporation
3.9.2 Adjusting Third Valve Option
The DSPP with the third valve option can be adjusted to accommodate any valve combination.
To adjust the V1 and V2 Z height (Figure 3-6):
1. Remove the four (4) screws holding the applicator bracket.
2. Move the applicator bracket up or down to the desired height.
3. Re-install the four (4) screws.
Item Description
1 Applicator Bracket
2 Screws (4)
Figure 3-6 Adjusting V1 and V2 Z Height
1
2