SIPLACE X-Series (SIPLACE X-Series S, from SC 708.1) Edition 05/2015 EN User manual.pdf - 第274页
5 Working with the machine User manual SIPLACE X-Series 5.4 Switching off the SIPLACE line From software ver sion 708.1 Version 05/2015 274 5.4 Switching off the SIPLACE line 5 5.4.1 Switching off the st ations T o switc…

User manual SIPLACE X-Series 5 Working with the machine
From software version 708.1 Version 05/2015 5.3 Switching on the SIPLACE line
273
5
Fig. 5.3 - 2 Flow chart - switching on the "SIPLACE line"
Station computer
Switch on
Check setup
(configure feeder modules
Teach fiducials
Load board data
Press start button
Wait for reference run
Move board in
Wait for PCB
Check setup
(if table marked red
If required: change nozzle configuration
Nozzle check
Fiducials
OK?
Track error
Placement
Check setup
Fill up tracks
Placement
PCB in output conveyor
Italics: Performed or reported by the station
Yes
Yes
No
No
Presettings at machine
Download assistant
Programming system
Tasks
Confirm conversion in download
assistant
Bold lettering: job to be performed by op-
erator

5 Working with the machine User manual SIPLACE X-Series
5.4 Switching off the SIPLACE line From software version 708.1 Version 05/2015
274
5.4 Switching off the SIPLACE line
5
5.4.1 Switching off the stations
To switch off the stations, proceed as follows:
End all placement procedures, so that there are no more boards in the machine.
Check whether the Z axes of all placement heads are in their uppermost end positions.
Check whether there are still components on the placement heads and remove these.
Close the station computer software in the view
Settings --> Machine Settings --> Shut Down Machine...
Once the computer has been shut down, switch off the station at the main switch.
5.4.2 Exiting SIPLACE Pro (Windows)
In the SIPLACE Pro menu, select Object --> Close.
Close all other programs on the computer.
Select Shut down from the Windows Start menu.
CAUTION
Before you switch off the line, observe the following procedures.

User manual SIPLACE X-Series 5 Working with the machine
From software version 708.1 Version 05/2015 5.5 The user interface
275
5.5 The user interface
The user interface is divided into the following areas.
5
Fig. 5.5 - 1 User interface components in the "Production" (example of SIPLACE X4i shown) view
Legend
(1) Status field (status and error display)
(2) Processing area / display area
(3) Toolbar
(4) Information line
(5) View of changed configurations and additional options e.g. barcode mode
(1)
(2)
(3)
(4)
(5)