SIPLACE X-Series (SIPLACE X-Series S, from SC 708.1) Edition 05/2015 EN User manual.pdf - 第49页
User manual SIPLACE X-Series 2 Operational safety From software version 708.1 Version 05/2015 2.1 Safety instructions 49 2.1.5 Safety instructions on permanent magnet s Powerful permane nt magnets a r e used for the line…
2 Operational safety User manual SIPLACE X-Series
2.1 Safety instructions From software version 708.1 Version 05/2015
48
2.1.3.3 Safety of plant and equipment
Never make changes, however minor, unless you are totally aware of the effect they will have
on the overall functioning of the system.
The stations must always be set up, retooled and maintained by appropriately trained person-
nel.
Do not make modifications to the safety equipment. In particular, NEVER deactivate circuit-
breakers or remove safety devices.
2.1.4 Safety instructions for laser units
Permission to operate components that are classified as lasers is withdrawn if
– Mechanical damage to the unit is observed, or
– Any work is done on the mechanical or electrical parts of the unit. Even damaged or miss-
ing screw locking paint on laser components (e.g. cover plates, fasteners, adjusting po-
tentiometer) counts as work.
– Only ASM Assembly Systems GmbH&Co.KG service engineers or the machine owner's
service engineers, who have been trained by ASM, may replace laser components.
– Repairs to laser assemblies may only be performed by ASM Assembly Systems
GmbH&Co.KG at their factory.

User manual SIPLACE X-Series 2 Operational safety
From software version 708.1 Version 05/2015 2.1 Safety instructions
49
2.1.5 Safety instructions on permanent magnets
Powerful permanent magnets are used for the linear motors of the X and Y axes.
2
2
2
DANGER
Danger to life from powerful magnetic fields inside the machine!
When protective covers are opened inside the machine, the life of persons with the fol-
lowing passive or active implants is put at risk:
– Pacemakers
– Defibrillators
– Insulin pumps etc.
At-risk people must not stand in the immediate vicinity of the machine.
WARNING
DANGER OF CRUSHING!
There is a danger of crushing for persons with passive metal implants (e.g. plates,
screws).
Never reach into the machine when the protective covers are open and do not bend
over the open machine.
Do not bring any metal objects into the danger area.
CAUTION
Data loss due to powerful magnetic fields!
There is a risk that the powerful magnetic fields could corrupt data on data media or credit
cards and check cards.
Keep data carriers and check cards away from the machine.

2 Operational safety User manual SIPLACE X-Series
2.1 Safety instructions From software version 708.1 Version 05/2015
50
Fig. 2.1 - 1 Position of the permanent magnets for the linear drives (example of SIPLACE X4i S shown)
(1) Permanent magnets for X linear motors
(2) Permanent magnets for Y linear motors
Please note the following points when working on the permanent magnets:
People with active implants (e.g. heart pacemakers) or other ferromagnetic prostheses are
expressly prohibited from working on or coming near these devices. Always keep a safe dis-
tance from the linear motor.
The powerful magnetic forces of attraction mean that particular caution is needed in the im-
mediate vicinity of the magnet track and of the moving primary part. Never move heavy or
wide objects made of steel or iron manually into the vicinity of the magnet track. The magnetic
force of attraction is not visible, so its effects in the vicinity of the magnet track are generally
underestimated. The magnetic attraction can start suddenly, and can reach several thousand
Newtons in the vicinity of ferromagnetic objects (made of steel or iron) of similar size to the
magnet track.