SIPLACE X-Series (SIPLACE X-Series S, from SC 708.1) Edition 05/2015 EN User manual.pdf - 第384页

6 Station extensions User manual SIPLACE X-Series 6.8 Docking station for the component trolley of the SIPLACE X-Series From software ver sion 708.1 Version 05/2015 384 6 F i g. 6.8 - 2 Do c kin g st a t ion - dimens ion…

100%1 / 430
User manual SIPLACE X-Series 6 Station extensions
From software version 708.1 Version 05/2015 6.8 Docking station for the component trolley of the SIPLACE X-Series
383
Legend for fig. 6.8 - 1, page 382
(1) Docking station
(2) X-Series COT insert
(3) Protective plate with warning sign W204
(4) Rails for guiding and docking the changeover table
(5) Clamping lever for locking the component trolley
(6) EDIF (energy and data interface)
The main tasks performed by the docking station are as follows:
Supply of energy to the component trolley and X feeder modules
Supply of compressed air to the component trolley and X feeder modules
Provision of an infrastructure for communication between the pre-setup location PC and
the feeder modules
With the help of the docking station, the operator can perform function tests to the X feeder mod-
ules outside the production environment and can check the setup. There are two rows, each with
four docking stations, connected via the CAN bus of the pre-setup PC. Each docking station has
its own power and compressed air connection.
The COT insert (item 2 in fig. 6.8 - 1
, page 382) for the docking station can be adjusted to the
required PCB conveyor height. To perform the pre-setup tasks, the component trolley is pushed
into the docking station (item 1 in fig. 6.8 - 1
, page 382). The component trolley slides along the
docking unit rails, with the roller bearings on the side of the component trolley, up to the energy
and data interface connection. The changeover table with the feeder module EDIF is positioned
precisely in relation to the EDIF (item 5 in fig. 6.8 - 1
, page 382) of the COT insert and fixed in this
position with the two clamping levers. The protective plates (item 3 in fig. 6.8 - 1
, page 382) pre-
vent access to the component trolley rollers, once these are pushed into the docking station.
6 Station extensions User manual SIPLACE X-Series
6.8 Docking station for the component trolley of the SIPLACE X-Series From software version 708.1 Version 05/2015
384
6
Fig. 6.8 - 2 Docking station - dimensions in millimeters, connection points
Legend for fig. 6.8 - 2, page 384
(1) Compressed air connection
(2) CAN bus connection
(3) Power supply connection
6.8.2 Technical data
6
Dimensions
Length x width 950 mm x 930 mm
Height 864 mm for 900 mm PCB conveyor height
894 mm for 930 mm PCB conveyor height
914 mm for 950 mm PCB conveyor height
Weight 120 kg
Compressed air pressure val-
ues
p
min
p
max
0.5 MPa (5.0 bar)
1.0 MPa (10.0 bar)
User manual SIPLACE X-Series 6 Station extensions
From software version 708.1 Version 05/2015 6.8 Docking station for the component trolley of the SIPLACE X-Series
385
6
6
6.8.3 Dimensions of docking station with docked component trolley
6
Fig. 6.8 - 3 Docking station with docked component trolley - dimensions in millimeters
(1) Component trolley
(2) Docking station
Compressed air connection Connection plug KS 2-M5-A
Compressed air consumption 50 Nl/min
*a
Supply voltage 88 - 264 V~
Rated current 3.5 A (230 V~)
7 A (115 V~)
Nominal apparent power 0.8 kW
Fuse 2 x 8 A